LYNXR-2 Series Installation and Setup Guide Mechanics of Programming Interactive Menu Mode Programming (✻56, ✻80, ✻81, ✻83, ✻84, ✻85) Press [✻] + interactive mode No. (i.e., ✻56). The keypad will display the first of a series of prompts. A detailed procedure (with displays of prompts) is provided in later sections of this manual. ✻56 Enhanced Zone Programming Mode Interactive menu mode used for programming zone attributes and report codes. Refer to the ✻56 Enhanced Zone Programming Mode section for procedure. ✻80 Device Programming Menu Mode Interactive menu mode for programming Powerline Carrier Devices. Refer to the ✻80 Device Programming Menu Mode section for detailed procedure. ✻81 Zone Lists Menu Mode Interactive menu mode for programming zone lists for Powerline Carrier Devices. Refer to the ✻81 Zone List Menu Mode section for detailed procedure. ✻83 Enhanced Sequential Mode Interactive menu mode used to enter RF transmitter serial numbers. Refer to the ✻83 Enhanced Sequential Mode section for detailed procedure. ✻84 Assign Zone Voice Descriptors Interactive menu mode used to assign descriptors to each zone. These descriptors will be announced whenever the system announces an event involving a zone. ✻85 Record Custom Voice Descriptors Interactive menu mode used to record custom descriptors for use with each zone. ✻96 Initialize Download ID and Subscriber Account Number for Downloading Entering ✻96 resets all subscriber account numbers and CSID in preparation for an initial download. Loading Factory Defaults ✻97 To load the factory defaults, enter ✻97, then press number 1, 2, 3, or 4 to select from default tables 1-4, or press "0" if you are not selecting a default table. Refer to the Programming Default Tables section of this manual to view the tables. If a default table is loaded, any data that has already been programmed into the system will be changed according to the default table selected! Exiting Program Mode ✻98 Exits program mode and inhibits re-entry into the Expert or Voice Prompt Programming modes using the Installer Code. ✻99 Exits program mode but allows re-entry into the Expert Program mode using Installer Code (4112) + 800 or into the Voice Prompt Programming mode using Installer Code (4112) + 888. Note: After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset delay, press [#] + [0]. Pass-Thru Programming This mode allows the Installer to use the LYNXR-2 Series keypad and display to program the communications device that is connected to the LYNXR-2 Series. Refer to the communications device's installation instruction to determine whether this feature is supported. Entering Pass-Thru Programming mode 1. After power-up, enter the Installer Code (4112) + 899. 2. Once you have entered Pass-Thru Programming mode "PtP" will be displayed on the keypad. 3. Refer to the Installation Instructions for the LRR/IP Communications Device being installed for additional programming information. LYNXR-2 Series will abort this mode: • When it receives an abort command from the new communications device. • If it fails to communicate with a communications device after 20 attempts. • 30 minutes after the last key has been pressed. - 18 -