LYNXR-2 Series Installation and Setup Guide Data Field Descriptions ✻49 Split/Dual Reporting To Primary 0 = All reports 1 = Alarms, Restore, Cancel 2 = All except Open/Close, Test 3 = Alarms, Restore, Cancel 4 = All except Open/Close, Test 5 = All reports To Secondary None, unless primary fails, then all Others Open/Close, Test All All All To Primary 6 = All reports except Open/Close 7 = All reports 8 = All reports 9 = All reports except Open/Close To Paging Number Alarms, Open/Close ‡, Troubles Alarms, Troubles Alarms, Open/Close ‡, Troubles Open/Close ‡ To Primary 10= All reports except Open/Close 11 = All reports 12= All reports 13= All reports except Open/Close To Follow Me System Phone Number Alarms, Open/Close ‡, Troubles Alarms, Troubles Alarms, Open/Close ‡, Troubles Open/Close ‡ *Recent close report is sent to primary number ‡ Will report Users 0, 5-8, and, if using wireless button-type devices, will report the zone number of the arm or disarm button 26-33. All other zones and users are not reported. This field is used to select a reporting option as follows: Enter: 0 - 5 when reporting to telephone receivers. 6 - 9 when reporting to a pager is desired. 10 - 13 when reporting to an aux telephone receiver. Note: If you are installing a communications module that has voice communications capability (i.e.; GSMVL), refer to Field *55 notes for additional information. Pager Report Format Options 6-9 send reports to the primary phone number, in a format defined in Field ✻48, and send reports to a pager, which has its phone number entered as the secondary phone number in Field ✻42. The pager report is a 7-digit code, with optional 16-digit prefix, in the following format: AAAAAAAAAAAAAAAA-EEE-0NNN where: AAA = Optional 16 digits for PIN number, etc. See Field ✻88 for full description of these characters. EEE = 3-digit Event Code as follows: 911 = Alarm (NN = zone number) 101 = Open, system disarmed (NN = user no.) 102 = Close, system armed (NN = user no.) 811 = Trouble (NN = zone no.) 0 = Always displayed before 3-digit user/zone no. NNN = 3-digit user number or zone number, depending on the type of event (EEE) that occurred. Follow Me System Report Format Options 10-13 send reports to the primary phone number, in a format defined in Field ✻48, and sends voice message to the secondary phone number entered in Field ✻42. The message is a repeatable system status announcement. If the manual paging option has been programmed in Field ✻87, the message will repeat "system, system.....". The message can be terminated by pressing any key on the telephone keypad. Field ✻50: Field *50 is used to program different features in the LYNXR-2 and LYNXR-2SIA controls. Please be sure that you use the correct field for the control being installed. ✻50 15-Second Dialer Delay (Burglary) Note: This field applies only to the LYNXR-2 control. LYNXR-2 SELECTIONS 0 = no dialer delay 1 = provide 15-second delay of burglary alarm report when armed away If enabled, provides delay of burglary report to the central station, and allows time for the subscriber to avoid a false alarm transmission. The delay applies only to zone type 3 and 5 alarms and not to zone type 24 alarms (silent burglary) or to 24-hour zone types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm), which are always sent as soon as they occur. UL installations: must be 0 (no delay) ✻50 Burglary Abort Window Note: This field applies only to the LYNXR-2SIA control. LYNXR-2SIA SELECTIONS 1 = 15-second abort window 2 = 30-second abort window 3 = 45-second abort window This provides the option for an Abort Window for Burglary zone types that report to the central station. This feature allows time for the subscriber to avoid a false alarm transmission. This feature does not apply to zone type 9 or 16 alarms (Supervised Fire) or to 24-hour zone types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm), which are always sent as soon as they occur. SIA The burglary abort window must be set to a minimum of 15 seconds. The sum of the burglary abort window entered in ✻50 and the entry delays entered in either Field ✻35 or ✻36 should not exceed 1 minute. Note: The LYNXR-2SIA control validates the data entered in this field. If the selection is not valid the control will emit a single long beep indicating that the selection has been rejected. The control replaces the selection with the default value "2", which is displayed on the keypad, and advances to the next field. - 27 -