Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste Installation Guid - Page 16

Series Transmitter Loop Numbers - wireless security system

Page 16 highlights

LYNXR-2 Series Installation and Setup Guide Installing Wireless Zones 5800 Series Transmitter Loop Numbers (Refer to this information when programming transmitters) The following illustration shows the compatible transmitters, their associated input types and loop designations. LOOP 1 LOOP 4 YOU MUST ENROLL THIS BUTTON LOOP 3 LOOP 2 LOOP 1 LOOP 1 5800CO ENROLL AS "RF" 5800Micra ENROLL AS "RF" LOOP 1 LOOP 4 YOU MUST ENROLL THIS BUTTON ON OFF LOOP 3 LOOP 2 LOOP 1 5800RL SET HOUSE ID 5800SS1 ENROLL AS "RF" LOOP 2 LOOP 4 LOOP YOU MUST ENROLL ON OFF 1 2 THIS BUTTON 3 3 LOOP 1 4 5 8 0 0 WAV E PROGRAM HOUSE ID 5801 ENROLL AS "UR OR"RF" 5802MN ENROLL AS "UR" OR "RF" LOOP 1 LOOP 1 LOOP 1 5802MN2 ENROLL AS "UR" OR "RF" 5804/5804E ENROLL AS "BR" 5804BD/5804BDV ENROLL AS "BR" PROGRAM HOUSE ID 5805-6 ENROLL AS "BR" 5806/5806W3/5807 5808/5808LST/5808W3 ENROLL AS "RF" 5809 ENROLL AS "RF" 5814 ENROLL AS "RF" LOOP 2 (REED) LOOP 1 (TERMINALS) ALTERNATE POSITION FOR LOOP 2 LOOP 2 (REED) LOOP 1 (TERMINALS) 5816 ENROLL AS "RF" 5816MN ENROLL AS "RF" LOOP 1 (TEMP SENSOR) 5816TEMP ENROLL AS "RF" LOOP 1 (PRIMARY) LOOP 2 (AUX. CENTER) LOOP 3 (AUX. RIGHT) 5817 ENROLL AS "RF" LOOP 1 5818 ENROLL AS "RF" LOOP 2 (REED) LOOP 3 (TERMINALS) LOOP 1 (TERMINALS) 5819 ENROLL AS "RF" LOOP 2 (REED) LOOP 3 (TERMINALS) LOOP 1 (INTERNAL SHOCK SENSOR 5819S (WHS & BRS) ENROLL AS "RF" 5820/5820L ENROLL AS "RF" 5821 ENROLL AS "RF" LOOP 1 (MOTION) ARMED READY MIC MESSAGE LOOP 1 (SOUND) 5828/5828V PROGRAM HOUSE ID 5849 ENROLL AS "RF" (((GRYeereldleo)nw)) 5850 (GBD) ENROLL AS "RF" 5853 ENROLL AS "RF" SERIAL #1 LOOP 3 SERIAL #1 LOOP 4 SERIAL #2 LOOP 3 AWAY STAY 1 2 3 4 SERIAL #1 LOOP 2 SERIAL #1 LOOP 1 SERIAL #2 LOOP 2 5878 ENROLL AS "BR" 5890/5890PI ENROLL AS "RF" 5894PI ENROLL AS "RF" 5897 ENROLL AS "RF" 5800-002-V0 Notes: (1) Loop 4 must be enrolled on the 5801, 5804, 5804BD, 5804BDV and 5804E transmitters, whether or not the loop is used. (2) 5804E encrypted (High-Security) devices must be activated while the system is in Go/No Go Test Mode. Refer to the transmitter's installation instructions for complete details. The system will confirm enrollment of the encrypted device by beeping two times. (3) The 5806 smoke detector must be used in SIA applications. UL The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5814, 5816TEMP, 5819, 5819S(WHS & BRS), 5828/5828V and 5850(GBD) wireless transmitters have not been evaluated by UL. - 16 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

LYNXR-2 Series Installation and Setup Guide
- 16 -
Installing Wireless Zones
5800 Series Transmitter Loop Numbers
(Refer to this information when programming transmitters)
The following illustration shows the compatible transmitters, their associated input types and loop
designations.
LOOP 1
5806/5806W3/5807
5808/5808LST/5808W3
ENROLL AS
"RF"
LOOP 1
5809
ENROLL AS
"RF"
5818
ENROLL AS
"RF"
LOOP 1
LOOP 1
5814
ENROLL
AS
"RF"
5800-002-V0
LOOP 1
(MOTION)
5897
ENROLL AS
"RF"
5890/5890PI
ENROLL AS
"RF"
LOOP 1
5802MN
ENROLL AS
"UR" OR "RF"
5805-6
ENROLL AS
"BR"
5804BD/5804BDV
ENROLL AS
"BR"
PROGRAM HOUSE ID
LOOP 4
YOU MUST
ENROLL
THIS BUTTON
LOOP
3
LOOP 1
LOOP 2
5804/5804E
ENROLL AS "BR"
5816TEMP
ENROLL AS
"RF"
LOOP 1
(TEMP
SENSOR)
5817
ENROLL AS
"RF"
LOOP 2
(AUX.
CENTER)
LOOP 1
(PRIMARY)
LOOP 3
(AUX.
RIGHT)
5816
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
LOOP 2
(REED)
5816MN
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
LOOP 2
(REED)
LOOP 3
(TERMINALS)
5828/5828V
PROGRAM
HOUSE ID
5821
ENROLL AS
"RF"
5820/5820L
ENROLL AS
"RF"
5819S (WHS & BRS)
ENROLL AS
"RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
5819
ENROLL AS
"RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
5800WAVE
PROGRAM
HOUSE ID
5800Micra
ENROLL AS "RF"
5800CO
ENROLL AS "RF"
5801
ENROLL AS
"UR OR"RF"
5800SS1
ENROLL AS "RF"
5800RL
SET
HOUSE ID
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
5849
ENROLL AS
"RF"
5894PI
ENROLL AS
"RF"
LOOP 1
(SOUND)
5802MN2
ENROLL AS
"UR" OR "RF"
LOOP
1
LOOP
1
5878
ENROLL AS
"BR"
5853
ENROLL AS
"RF"
5850 (GBD)
ENROLL AS
"RF"
(Green)
(Red)
(Yellow)
ARMED
READY
4
3
2
1
OFF
ON
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 1
LOOP 2
LOOP 3
SERIAL #1
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 3
SERIAL #1
LOOP 2
SERIAL #1
LOOP 1
SERIAL #2
LOOP 2
3
AWAY
STAY
1
2
4
OFF
ON
Notes:
(1)
Loop 4 must be enrolled on the 5801, 5804, 5804BD, 5804BDV and 5804E transmitters, whether or not the
loop is used.
(2)
5804E encrypted (High-Security) devices must be activated while the system is in Go/No Go Test Mode. Refer
to the transmitter’s installation instructions for complete details. The system will confirm enrollment of the
encrypted device by beeping two times.
(3) The 5806 smoke detector must be used in SIA applications.
UL
UL
UL
UL
The
5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5814, 5816TEMP, 5819, 5819S(WHS & BRS),
5828/5828V and 5850(GBD) wireless transmitters
have not been evaluated by UL
.