Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste Installation Guid - Page 22
Single Alarm Sounding Per Zone - 3 manual
UPC - 781410916135
View all Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
LYNXR-2 Series Installation and Setup Guide Data Field Descriptions ✻29 Daylight Savings Time Start/ End Month 0 = do not display the time 1 = display the time ✻30 Daylight Savings Time Start/ End week 0 = disable 1 = first weekend of month 2 = second weekend 3 = third weekend 4 = fourth weekend 5 = last weekend 6 = next to last 7 = 3rd from last ✻31 Single Alarm Sounding Per Zone (per armed period) LYNXR-2 SELECTIONS 0 = no limit on alarm sounding per zone 1 = limit alarm sounding to once per arming period for a given zone LYNXR-2SIA SELECTIONS 0 = Alarm Sounding Per Zone will be the same as the Swinger Shutdown" set in field *92 1 = limit alarm sounding to once per arming period for a given zone ✻32 Sounder Timeout 0 = yes, sounder timeout after time programmed in field ✻33 1 = no sounder timeout; continue sounding until manually turned off Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12. Enter the appropriate start and end weekend of the month. This field applies only to burglary zones (zone response types 1-5, 10), and affects long range radio reporting but does not affect central station reporting. Note: This field applies only to the bell and does not affect keypad sounds. UL installations: must be 0 (no limit) This Control complies with NFPA requirements for temporal pulse sounding of fire and carbon monoxide (CO) notification appliances. Temporal pulse sounding for a fire alarm consists of the following: 3 pulses - pause - 3 pulses - pause - 3 pulses. . . ✻33 Alarm Bell Timeout 0 = No timeout 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes Temporal pulse sounding for a CO alarm consists of the following: 4 pulses - pause - 4 pulses - pause - 4 pulses - pause. . . This field determines whether the external sounder will shut off after time allowed, or continue until manually turned off. UL installations: must be set for a minimum of 4 min (option 1) Fields ✻34-✻36: Fields *34, *35 and *36 are used to program different options in the LYNXR-2 and LYNXR2SIA controls. Please be sure that you use the correct field for the control being installed. Note: The LYNXR-2 SIA control validates the data entered in fields *34 - *36. If the selection is not valid the control will emit a single long beep indicating that the selection has been rejected. The control replaces the selection with the default value which is displayed on the keypad. ✻34 Exit Delay LYNXR-2 SELECTIONS 00-99 = exit delay time in seconds LYNXR-2SIA SELECTIONS Entries from 45-97 Entered Value 45-96 97 Delay in Seconds 45-96 120 The system will wait the time entered before sounding an alarm if the exit door is left open after the system has been armed. UL installations: must be set for a maximum of 60 seconds Note: The LYNXR-2SIA control validates the data entered in this field. If the selection is not valid the control will emit a single long beep indicating that the selection has been rejected. The control replaces the selection with the default value "60", which is displayed on the keypad, and advances to the next field. SIA: Exit Delay must be set to a minimum of 45 seconds. - 22 -