To put the boundary wire in a slope, Passages, To make an island, cutting result.

Page 23 highlights

• Make an eyelet (F) where the guide wire is to be connected to the boundary wire. 3.4.3.1 To put the boundary wire in a slope The product can operate in 70% slopes. Slopes that are too steep must be isolated with the boundary wire. The gradient (%) is calculated as height per m. Example: 10 cm / 100 cm = 10%. 10% 100 cm/40" 10 cm/4" Note: If a passage is less than 2 m / 6.5 ft. wide, install a guide wire through the passage. A dead end must be a minimum of 2.5 m / 8.5 ft. wide. >2 m / 7 ft >2.5 m / 8.5 ft • For slopes up to 50% steep inside the work area, the product will operate normally. Keep a distance of 1.5 m / 5 ft between the boundary wire and obstacles, or between obstacles. • For slopes between 50-70% steep, make sure that there are no obstacles in the slope. There must be a distance of 1.5 m / 5 ft from the bottom of the slope to the boundary wire. > 1.5 m / 5 ft > 1.5 m / 5 ft >60 cm / 12" Max. distance >30 cm / 12" > 1.5 m / 5 ft >2 m / 7 ft 0% - 50% 50% - 70% • For slopes adjacent to a public road, put a fence or a protective wall along the outer edge of the slope. 3.4.3.2 Passages A passage is a section that has boundary wire on each side and that connects 2 work areas. The passage must be a minimum of 2 m / 6.5 ft wide to get a good cutting result. Short passages can be as narrow as 60 cm / 2 ft., if a guide wire is installed through the passage. A long narrow passage can have a negative impact of the cutting result. Note: Make sure that the guide wire has as much free area as possible to the left of the guide wire when facing the charging station. Minimum distance between the guide wire and boundary wire is 30 cm / 12 in. 3.4.3.3 To make an island CAUTION: Do not put a section of boundary wire across the other. The sections of boundary wire must be parallel. 1404 - 002 - Installation - 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

Make an eyelet (F) where the guide wire is
to be connected to the boundary wire.
3.4.3.1 To put the boundary wire in a slope
The product can operate in 70% slopes. Slopes
that are too steep must be isolated with the
boundary wire. The gradient (%) is calculated as
height per m. Example: 10 cm / 100 cm = 10%.
10 cm/4"
100 cm/40"
10%
For slopes up to 50% steep inside the work
area, the product will operate normally.
Keep a distance of 1.5 m / 5 ft between the
boundary wire and obstacles, or between
obstacles.
For slopes between 50-70% steep, make
sure that there are no obstacles in the slope.
There must be a distance of 1.5 m / 5 ft from
the bottom of the slope to the boundary wire.
> 1.5 m / 5 ft
> 1.5 m / 5 ft
0% - 50%
50% - 70%
> 1.5 m / 5 ft
For slopes adjacent to a public road, put a
fence or a protective wall along the outer
edge of the slope.
3.4.3.2 Passages
A passage is a section that has boundary wire on
each side and that connects 2 work areas. The
passage must be a minimum of 2 m / 6.5 ft wide
to get a good cutting result. Short passages can
be as narrow as 60 cm / 2 ft., if a guide wire is
installed through the passage. A long narrow
passage can have a negative impact of the
cutting result.
Note:
If a passage is less than 2 m / 6.5 ft. wide,
install a guide wire through the passage.
A dead end must be a minimum of 2.5 m / 8.5 ft.
wide.
>2 m / 7 ft
>2.5 m / 8.5 ft
>2 m / 7 ft
Max.
distance
>60 cm / 12"
>30 cm / 12"
Note:
Make sure that the guide wire has as much
free area as possible to the left of the guide wire
when facing the charging station. Minimum
distance between the guide wire and boundary
wire is 30 cm / 12 in.
3.4.3.3 To make an island
CAUTION:
Do not put a section of
boundary wire across the other. The
sections of boundary wire must be
parallel.
1404 - 002 -
Installation -
23