IBM 621858U Installation Guide - Page 49

technician

Page 49 highlights

Table 2. POST error messages (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the part listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error codes Description Action 1803 A PCI adapter has requested memory above 1. If the error code indicates a particular 1 MB. PCI or PCI-Express slot or device, remove the device. 2. Reseat each adapter. Note: If an error LED is lit on an adapter, reseat that adapter first; if no LEDs are lit, reseat each adapter one at a time, restarting the computer each time, to isolate the failing adapter. 3. Replace the following components one at a time, in the order shown, restarting the computer each time: a. Failing adapter b. (Trained service technician only) System board 1804 A PCI adapter has requested memory below 1 MB. 1. If the error code indicates a particular PCI or PCI-Express slot or device, remove the device. 2. Reseat each adapter. Note: If an error LED is lit on an adapter, reseat that adapter first; if no LEDs are lit, reseat each adapter one at a time, restarting the computer each time, to isolate the failing adapter. 3. Replace the following components one at a time, in the order shown, restarting the computer each time: a. Failing adapter b. (Trained service technician only) System board 1805 A PCI option ROM checksum error occurred. 1. Remove the failing adapter. 2. Reseat each adapter. Note: If an error LED is lit on an adapter, reseat that adapter first; if no LEDs are lit, reseat each adapter one at a time, restarting the computer each time, to isolate the failing adapter. 3. Replace the following components one at a time, in the order shown, restarting the computer each time: a. Failing adapter b. (Trained service technician only) System board Chapter 5. Solving problems 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

Table
2.
POST
error
messages
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
part
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
codes
Description
Action
1803
A
PCI
adapter
has
requested
memory
above
1
MB.
1.
If
the
error
code
indicates
a
particular
PCI
or
PCI-Express
slot
or
device,
remove
the
device.
2.
Reseat
each
adapter.
Note:
If
an
error
LED
is
lit
on
an
adapter,
reseat
that
adapter
first;
if
no
LEDs
are
lit,
reseat
each
adapter
one
at
a
time,
restarting
the
computer
each
time,
to
isolate
the
failing
adapter.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Failing
adapter
b.
(Trained
service
technician
only)
System
board
1804
A
PCI
adapter
has
requested
memory
below
1
MB.
1.
If
the
error
code
indicates
a
particular
PCI
or
PCI-Express
slot
or
device,
remove
the
device.
2.
Reseat
each
adapter.
Note:
If
an
error
LED
is
lit
on
an
adapter,
reseat
that
adapter
first;
if
no
LEDs
are
lit,
reseat
each
adapter
one
at
a
time,
restarting
the
computer
each
time,
to
isolate
the
failing
adapter.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Failing
adapter
b.
(Trained
service
technician
only)
System
board
1805
A
PCI
option
ROM
checksum
error
occurred.
1.
Remove
the
failing
adapter.
2.
Reseat
each
adapter.
Note:
If
an
error
LED
is
lit
on
an
adapter,
reseat
that
adapter
first;
if
no
LEDs
are
lit,
reseat
each
adapter
one
at
a
time,
restarting
the
computer
each
time,
to
isolate
the
failing
adapter.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Failing
adapter
b.
(Trained
service
technician
only)
System
board
Chapter
5.
Solving
problems
37