IBM 847691U Hardware Maintenance Manual - Page 143

Flash Utility Diskette, Flash Utility, Diskette, procedure see Remote administration

Page 143 highlights

6. Pull outward on the retainer tabs. 7. If you replace the microprocessor with one that has a different speed, you might have to change the switch settings on the system board. To locate the switches, see "System board illustration" on page 142. For information about the appropriate switch settings, see "Microprocessor speed switches settings" on page 153, or see the label inside the server side cover. 8. If you receive the error code 167 after you install a new microprocessor, run the Flash Utility program. Insert the Flash Utility Diskette into the primary diskette drive and run the flash program. Follow the instructions in the program. Note If you have not already done so, go to http://www.ibm.com/support/ on the World Wide Web and download the appropriate flash update program. Review the applicable README files, and use this information to create a Flash Utility Diskette. Perform the POST/BIOS (flash) update procedure (see "Remote administration" on page 34 for additional information). 9. Because you installed a new microprocessor in the server, you must reconfigure the server. Follow the procedure described in "Configuration/Setup utility program menus" on page 24. Refer to the operating-system documentation. You might need to make changes so that the operating system recognizes the new microprocessor. 10. If you want to install or remove any other options, do so now. Otherwise, go to "Completing the installation" on page 77. IBM Netfinity 3000 - Type 8476 135

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270

6.
Pull outward on the retainer tabs.
7.
If you replace the microprocessor with one that has a
different speed, you might have to change the switch
settings on the system board.
To locate the switches,
see “System board illustration” on page
142. For
information about the appropriate switch settings, see
“Microprocessor speed switches settings” on
page
153, or see the label inside the server side
cover.
8.
If you receive the error code 167 after you install a
new microprocessor, run the Flash Utility program.
Insert the
Flash Utility Diskette
into the primary
diskette drive and run the flash program.
Follow the
instructions in the program.
Note
If you have not already done so, go to
http://www.ibm.com/support/ on the World Wide
Web and download the appropriate flash update
program.
Review the applicable README files,
and use this information to create a
Flash Utility
Diskette
.
Perform the POST/BIOS (flash) update
procedure (see “Remote administration” on
page
34 for additional information).
9.
Because you installed a new microprocessor in the
server, you must reconfigure the server.
Follow the
procedure described in “Configuration/Setup utility
program menus” on page
24.
Refer to the operating-system documentation.
You
might need to make changes so that the operating
system recognizes the new microprocessor.
10.
If you want to install or remove any other options, do
so now.
Otherwise, go to “Completing the
installation” on page
77.
IBM Netfinity 3000 - Type 8476
135