IBM 847691U Hardware Maintenance Manual - Page 177
FRU/Action, System Device Reset
View all IBM 847691U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 177 highlights
Diagnostic Error Code 001-035-XXX System Device Reset condition detected 001-036-XXX System Register error 001-038-XXX System Extension failure 001-039-XXX System DMI data structure error 001-040-XXX System IRQ failure 001-041-XXX System DMA failure 001-195-XXX System Test aborted by user 001-196-XXX System test halt, error threshold exceeded 001-197-XXX System test warning 001-198-XXX System test aborted 001-199-XXX System test failed, cause unknown 001-250-XXX System ECC error FRU/Action 1. System board 1. System board 1. Adapter card 2. System board 1. Flash the system 2. System board 1. Power-off/on system and re-test 2. System board 1. Power-off/on system and re-test 2. System board 1. Information 2. Re-start the test, if need to 1. Press F3 to review the log file. See "Viewing the test log" on page 14. 2. Re-start the test to reset the log file. 1. Make sure component that is called out is enabled and/or connected 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 1. If a component is called out, make sure it is enabled and/or connected 2. Flash the system and re-test 3. Go to "Undetermined problems" on page 198 1. Go to "Undetermined problems" on page 198. 2. Flash the system and re-test 3. Replace component under function test. 1. System board IBM Netfinity 3000 - Type 8476 169