Diagnostic Error Code 175-195-XXX Thermal Sensor(s) Test aborted by user 175-196-XXX Thermal Sensor(s) test halt, error threshold exceeded 175-197-XXX Thermal Sensor(s) test warning 175-198-XXX Thermal Sensor(s) test aborted 175-199-XXX Thermal Sensor(s) test failed, cause unknown 175-250-XXX 175-251-XXX Thermal Sensor(s) limit error 185-000-XXX Asset Security Test Passed 185-XXX-XXX Asset Security failure 185-278-XXX Asset Security Chassis Intrusion 201-000-XXX System Memory Test Passed 201-XXX-XXX System Memory error FRU/Action 1. Information 2. Re-start the test, if need to 1. Press F3 to review the log file. See "Viewing the test log" on page 14. 2. Re-start the test to reset the log file. 1. Make sure component that is called out is enabled and/or connected 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 1. If a component is called out, make sure it is enabled and/or connected 2. Flash the system and re-test 3. Go to "Undetermined problems" on page 198 1. Go to "Undetermined problems" on page 198. 2. Flash the system and re-test 3. Replace component under function test. 1. Check fans 2. Check Power supply 3. Microprocessor 4. System board 1. No action 1. Assure Asset Security Enabled 2. Flash system 3. System board 1. C2 Cover Switch 2. System board 1. No action 1. Replace the memory module called out by the test 2. System board 186 Netfinity Server HMM