IBM 847691U Hardware Maintenance Manual - Page 192
Go to Undetermined, Microprocessor Test Passed
View all IBM 847691U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 192 highlights
Diagnostic Error Code 086-198-XXX Mouse Port interface test aborted 086-199-XXX Mouse Port interface test failed, cause unknown 089-000-XXX Microprocessor Test Passed 089-XXX-XXX Microprocessor failure 089-195-XXX Microprocessor Test aborted by user 089-196-XXX Microprocessor test halt, error threshold exceeded 089-197-XXX Microprocessor test warning 089-198-XXX Microprocessor test aborted 089-199-XXX Microprocessor test failed, cause unknown FRU/Action 1. If a component is called out, make sure it is enabled and/or connected 2. Flash the system and re-test 3. Go to "Undetermined problems" on page 198 1. Go to "Undetermined problems" on page 198. 2. Flash the system and re-test 3. Replace component under function test. 1. No action 1. Microprocessor(s) 2. System board 1. Information 2. Re-start the test, if need to 1. Press F3 to review the log file. See "Viewing the test log" on page 14. 2. Re-start the test to reset the log file. 1. Make sure component that is called out is enabled and/or connected 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 1. If a component is called out, make sure it is enabled and/or connected 2. Flash the system and re-test 3. Go to "Undetermined problems" on page 198 1. Go to "Undetermined problems" on page 198. 2. Flash the system and re-test 3. Replace component under function test. 184 Netfinity Server HMM