IBM 8480 Hardware Maintenance Manual

IBM 8480 - Eserver xSeries 205 Manual

IBM 8480 manual content summary:

  • IBM 8480 | Hardware Maintenance Manual - Page 1
    ERserver IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 2
  • IBM 8480 | Hardware Maintenance Manual - Page 3
    ERserver IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 4
    information and the product it supports, read Appendix C, " these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes for products and services offered in the United States of America. IBM may not offer the products, services, or features discussed
  • IBM 8480 | Hardware Maintenance Manual - Page 5
    About this manual This manual contains diagnostic information, a Symptom-to-FRU index, service information, error codes, error messages, and configuration information for the IBM® ™ xSeries® 205. Eserver Important: The field replaceable unit (FRU) procedures are intended for trained servicers who
  • IBM 8480 | Hardware Maintenance Manual - Page 6
    iv IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 7
    Text messages 26 Starting the diagnostic programs 26 Diagnostic error message tables 28 Recovering from a POST/BIOS update failure 29 Power checkout 29 Troubleshooting the Ethernet controller 30 Network connection problems 30 Ethernet controller troubleshooting chart 31 Ethernet controller
  • IBM 8480 | Hardware Maintenance Manual - Page 8
    Power supply 73 Rear fan 74 Extender card 75 System board 77 CD-ROM drive 78 Diskette drive 79 Bezel release latch 80 Top/side cover 81 Handle assembly 82 Adapter retainer 83 Chapter 6. Symptom-to-FRU index 85 vi IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting
  • IBM 8480 | Hardware Maintenance Manual - Page 9
    7. Parts listing Type 8480 111 System 112 Keyboard CRUs 113 Power cords 114 Appendix A. Getting help and technical assistance 117 Before you call 117 Using the documentation 117 Getting help and information from the World Wide Web 117 Software service and support 118 Hardware service and
  • IBM 8480 | Hardware Maintenance Manual - Page 10
    viii IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 11
    service technician. In addition to this Hardware Maintenance Manual and Troubleshooting Guide, the following xSeries 205 Type 8480 documentation is provided with your server: v Installation Guide This printed publication contains setup and installation instructions. v Rack Installation Instructions
  • IBM 8480 | Hardware Maintenance Manual - Page 12
    potentially lethal or extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation. 2 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 13
    - Line in - Mic v Dual-channel bus mastering IDE controller v Support for IBM Remote Supervisor Adapter Acoustical noise emissions: v Sound power, idling: 5.1 bel maximum v Sound power, operating: 5.3 bel maximum Environment: v Air temperature: - Server on: 10° to 35°C (50.0° to 95.0°F). Altitude
  • IBM 8480 | Hardware Maintenance Manual - Page 14
    to release a diskette from the diskette drive. Diskette drive activity LED: When this LED is lit, it indicates that the diskette drive is in use. 4 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 15
    is flashing, it indicates that the hard disk drive is in use. Power-on LED: When this LED is lit, it indicates that the server is turned on. Power-control button: Press this button to turn the server on and off manually. Ethernet transmit/receive activity LED: When this LED on the Ethernet connector
  • IBM 8480 | Hardware Maintenance Manual - Page 16
    might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. 2 1 The server can be turned off in any of the following ways: 6 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 17
    your operating system supports this feature, and turn off the server. v If the operating system stops functioning, you can press and hold the power-control button for more than 4 seconds to turn off the server. v If the Wake on LAN feature turned on the server, the Wake on LAN feature can turn off
  • IBM 8480 | Hardware Maintenance Manual - Page 18
    8 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 19
    specifically designed for your IBM server. Use this CD during the initial installation of your server Boot Menu program is part of the BIOS code that comes with your server. You can use power-on-self-test (POST) error message is displayed. See the Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 20
    to access the full Configuration/Setup Utility menu. 3. Follow the instructions that appear on the screen. Use the Up Arrow (↑)and Down the server. You must set an administrator password to set a user password. 10 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 21
    then install the battery. See the Hardware Maintenance Manual and Troubleshooting Guide for instructions. To set a user password, complete the this setting, you must type a user password when you start the server. Setting the password check jumper The following illustration shows the location of
  • IBM 8480 | Hardware Maintenance Manual - Page 22
    new user password. Enabling Broadcom NetXtreme Gigabit Ethernet Boot Agent The Broadcom NetXtreme Gigabit Ethernet Boot Agent is part of the BIOS code that comes with your server. Agent, complete the following steps: 12 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 23
    system BIOS code and microcode (firmware) levels of supported options to determine whether a later level is available from the CD. You can perform updates without using diskettes. v Provides the Performance Optimizer program to easily tune your SCSI RAID adapter settings for your server environment
  • IBM 8480 | Hardware Maintenance Manual - Page 24
    options without using diskettes. - The SCSI RAID configuration program starts, leading you through the entire configuration process. - The Performance Optimizer program easily tunes your server for your environment. 14 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 25
    adapters might require switch settings, additional device drivers, and installation after the operating system is installed. See the documentation that comes with the adapter. 2. Diagnostics for your server come in BIOS code or on a separate diagnostics CD. Typical operating-system installation You
  • IBM 8480 | Hardware Maintenance Manual - Page 26
    the Device Drivers and IBM Enhanced Diagnostics CD that comes with your server. For updated information about configuring your Ethernet controller, go to the IBM Support Web site at http://www.ibm.com/pc/support/ and navigate to the area for your specific server type. From this area you can download
  • IBM 8480 | Hardware Maintenance Manual - Page 27
    The following sections provide instructions for starting the SCSISelect Utility program and descriptions of the menu choices available. Starting the SCSISelect Utility program Complete the following steps to start the SCSISelect utility program: 1. Turn on the server. 2. When the
  • IBM 8480 | Hardware Maintenance Manual - Page 28
    values, press F6; then, follow the instructions that appear on the screen. You . Before you can make updates, you must know the ID Failure screen might appear. Restart the server and watch the SCSISelect messages as each IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 29
    the following steps to use the Boot Menu program to change the startup sequence of your server: 1. Turn off the server. 2. Restart the server. 3. Press F12. 4. Select the startup device. The next time the server is started, it returns to the startup sequence set in the Configuration/Setup Utility
  • IBM 8480 | Hardware Maintenance Manual - Page 30
    20 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 31
    server diagnostic programs are stored on the IBM Enhanced Diagnostics CD. These programs provide the primary methods of testing the major components of the server. If you cannot determine whether a problem to "Undetermined problems" on page 108. 5. For power supply problems, see "Power checkout" on
  • IBM 8480 | Hardware Maintenance Manual - Page 32
    on page 25. If you receive an error, see Chapter 6, "Symptom-to-FRU index," on page 85. If the diagnostic programs were completed successfully and you still suspect a problem, see "Undetermined problems" on page 108. 22 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 33
    server. See "Diagnostic programs and error messages" on page 25 for more information. v Customized support page You can create a customized support page that is specific to your hardware, complete with Frequently Asked Questions, Parts Information, Technical Hints and Tips, and Downloadable files
  • IBM 8480 | Hardware Maintenance Manual - Page 34
    The SCSI RAID v Ensure that there are no duplicate SCSI IDs or IRQ assignments. program cannot v Ensure that the hard disk drive is connected properly. view all installed drives, or the NOS cannot be installed. 24 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 35
    on the IBM Enhanced Diagnostics CD. These programs are the primary method of testing the major components of your server. Diagnostic error messages indicate that a problem exists; they are not intended to be used to identify a failing part. Troubleshooting and servicing of complex problems that are
  • IBM 8480 | Hardware Maintenance Manual - Page 36
    World Wide Web at http://www.ibm.com/pc/support. Note: When using diagnostics with a USB Keyboard and Mouse attached, go into Setup and enable USB emulation. 1. Press F1 Config/Setup 2. Select Devices and I/O Ports 26 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 37
    Do the following to download the latest image of the IBM Enhanced Diagnostics from the World Wide Web and create a startable Enhanced Diagnostics diskette: 1. Go to the following World Wide Web site: http://www.ibm.com/pc/support/ 2. Download the diagnostics file for your server to a hard disk drive
  • IBM 8480 | Hardware Maintenance Manual - Page 38
    If diagnostic error messages appear that are not listed in the tables, make sure that your server has the latest levels of BIOS, Advanced System Management Processor, ServeRAID™, and diagnostics microcode installed. 28 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 39
    pins. 5. Replace any adapters that were removed and replace the support bracket and the cover. See the Option Installation Guide for instructions. Reconnect the power cords for the server and monitor to electrical outlets. 6. Insert the POST/BIOS update (flash) diskette into drive A, and turn on the
  • IBM 8480 | Hardware Maintenance Manual - Page 40
    server are using the same protocol. v Test the Ethernet controller. The way the Ethernet controller is tested depends on which operating system you are using (see the Ethernet controller device driver README files). 30 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 41
    find solutions to 10/100/1000 Mbps Ethernet controller problems that have definite symptoms. Table 2. Ethernet troubleshooting chart Ethernet controller problem FRU/actions The server stops running when loading device drivers. The PCI BIOS interrupt settings are incorrect. Check the following
  • IBM 8480 | Hardware Maintenance Manual - Page 42
    Ethernet controller might display messages from certain device drivers. The latest information available concerning these messages will be made available at the IBM Support Web site at http://www.ibm.com/pc/support. 32 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 43
    IBM xSeries 205 Type 8480 server. Eserver Note: The illustrations in this document might look slightly different from your hardware. Microprocessor Rear adapterretaining bracket Memory modules PCI extender board EMC shields Filler panels Drive cage Front adaptersupport bracket Frame-support
  • IBM 8480 | Hardware Maintenance Manual - Page 44
    , your system board and PCI extender board might look slightly different. Microprocessor and fan (U6) DIMM 2 DIMM 1 AGP PCI 1 PCI 2 PCI 3 PCI 4 PCI 5 Battery 34 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 45
    board connectors for internal cables. Microprocessor fan connector (CN3) Front fan connector (CN2) Rear fan (CN19) Microprocessor power Internal speaker connector Video connector Main power SCSI LED connector Primary IDE (PRI IDE) Secondary IDE (SEC IDE) Password check jumper (JP1) CMOS clear
  • IBM 8480 | Hardware Maintenance Manual - Page 46
    status LED (green) Ethernet activity LED (green) Ethernet port (RJ-45) P- P Serial port (COM) ASM Interconnect port (RJ-14) Error LED (amber) P- P Power LED (green) External power supply connector (not used) 36 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 47
    IBM xSeries 205 Type 8480 server, Eserver rotate the two front stabilizing feet a quarter turn towards the server, so they do not break. Before placing the server server. Do not place objects in front of the fans. v You have followed the instructions unpainted metal part of the server for at
  • IBM 8480 | Hardware Maintenance Manual - Page 48
    illustration shows the rear feet located on the bottom rear of the server. Release tab Feet (unlocked position) Release tab 3. Rotate the foot inward to the unlocked position; then, remove the foot from the server. 38 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 49
    as indicated. Note: The following illustration shows the rear feet located on the bottom rear of the server. Guides Feet (locked position) Guides 5. Rotate the foot outward until the foot locks into place. 6. Complete steps 2 through 5 for each foot. Attention: When you need to access the inside
  • IBM 8480 | Hardware Maintenance Manual - Page 50
    "Replacing the side cover" on page 59. Attention: For proper cooling and airflow, replace the side cover before turning on the server. Operating the server with the side cover removed might damage server components. 40 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 51
    the existing option. Complete the following steps to remove the frame-support bracket: 1. Pull out on the rear end of the frame-support bracket approximately 150 mm (6 in.). 2. Pull the rear end of the frame-support bracket away from the server and place the bracket aside. To reinstall the frame
  • IBM 8480 | Hardware Maintenance Manual - Page 52
    expansion slots 3 through 5. v The optional Remote Supervisor Adapter must be installed in PCI slot 1. v For a list of supported options for your server, go to http://www.ibm.com/pc/support/ on the World Wide Web. 42 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 53
    on page 119. 2. Turn off the server and all attached devices, and disconnect all external cables and power cords; then, remove the side cover. See instructions. It might be easier to route any cables before you install the adapter. 3. Remove the frame-support bracket. See "Removing the frame-support
  • IBM 8480 | Hardware Maintenance Manual - Page 54
    the frame-support bracket. 14. Replace the side cover. See "Replacing the side cover" on page 59 for details. 15. Reconnect the external cables and power cords; then, turn on the attached devices and the server. 44 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 55
    the SCSI LED connector. SCSI cable RAID adapter SCSI connector 4. If you have other adapters or support bracket. 8. Replace the side cover. See "Replacing the side cover" on page 59 for details. 9. Reconnect the external cables and power cords; then, turn on the attached devices and the server
  • IBM 8480 | Hardware Maintenance Manual - Page 56
    SCSI cable, observe these precautions: v Do not block the ventilated space in front of the fan assembly. v Do not route the SCSI cable over the memory board assembly. 46 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 57
    5. Route the SCSI cable from the backplane on the hot-swap drive cage (bays 5 to 7) to the internal channel connector on the RAID adapter. SCSI cable RAID adapter SCSI connector 6. If you have other options to install or remove, do so now; otherwise, go to "Replacing the side cover" on page 59.
  • IBM 8480 | Hardware Maintenance Manual - Page 58
    205 Type 8480 server comes with an IDE CD-ROM or Eserver DVD-ROM drive in bay 1, a 3.5-in., 1.44 MB diskette drive in bay 3, and a hard disk drive installed in bay 4. Bay 1 Bay 2 Bay 3 Bay 4 Bay 5 Bay 6 Bay 7 48 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 59
    a 3.5-in. slim-high removable-media drive only in bay 4. v The IBM xSeries 205 Type 8480 server supports only one diskette drive. v To install a 3.5-in. drive in a 5. the bay in which you want to install the drive. 3. Check the instructions that come with the drive to see if you need to set any
  • IBM 8480 | Hardware Maintenance Manual - Page 60
    server uses cables to connect IDE and SCSI devices to the power supply and to the system board. The following cables are provided: v Four-wire power cables connect the drives to the power supply as a primary device. 50 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 61
    power cords. 3. Remove the side cover. See "Removing the side cover" on page 40 for details. 4. Remove the frame-support bracket. See "Removing the frame-support bracket" on page 41. 5. Use a screwdriver to pry the filler panel and EMC shield away from the server are no serviceable parts inside the
  • IBM 8480 | Hardware Maintenance Manual - Page 62
    the new drive support bracket. 15. Replace the side cover. See "Replacing the side cover" on page 59 for details. 16. Reconnect the external cables and power cords; then turn on the attached devices and the server. 52 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 63
    the frame-support bracket" on page 41 for details. 5. If your server has hard disk drives preinstalled in the drive cage, disconnect the power and signal Attach the guide rails to the side of the drive using the screws provided. If you obtained your optional drive from IBM, the guide rails are blue
  • IBM 8480 | Hardware Maintenance Manual - Page 64
    support bracket. 13. Replace the side cover. See "Replacing the side cover" on page 59 for details. 14. Reconnect the external cables and power cords; then, turn on the attached devices and the server RAID server. 54 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 65
    hot-swap drive. The following illustration shows the rear connectors on the hot-swap-drive backplane, as viewed from the rear of the server. SCSI cable connector SCSI power cable connector I2C cable connector When you install hot-swap hard disk drives, install them in the following order: bay 7, bay
  • IBM 8480 | Hardware Maintenance Manual - Page 66
    a RAID adapter, you might need to reconfigure your disk arrays after installing hard disk drives. See the information that comes with your RAID adapter. 4. If you have other options to install or remove, do so now. 56 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 67
    memory in your server by installing memory modules. Your IBM xSeries 205 Type 8480 server uses industry-standard dual inline memory power cords; then remove the side cover. See "Removing the side cover" on page 40 for details. 3. Remove the frame-support bracket. See "Removing the frame-support
  • IBM 8480 | Hardware Maintenance Manual - Page 68
    clip and around an object that is not part of or permanently secured to the building structure server. Rope clip 6. Reconnect the external cables and power cords, and turn on the attached devices, and then the server. 58 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 69
    two front stabilizing feet are rotated outward so that they properly support the server. Rotate each individual foot outward 90 degrees. 4. Reconnect the external cables and power cords to the server; then, connect the power cords to electrical outlets. 5. Turn on the attached devices; then, turn
  • IBM 8480 | Hardware Maintenance Manual - Page 70
    cover" on page 59. 6. Turn on the server. 7. Start the Configuration/Setup Utility program and set configuration parameters. v Set the system date and time. v Set passwords if necessary. v Save the configuration. 60 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 71
    printer, a keyboard, or a mouse. You can connect a number of optional external devices to the connectors on the rear of the server, such as a printer, a keyboard, or a mouse. Power cord Mouse Keyboard Parallel Serial 2 Serial 1 USB 1 USB 2 Ethernet Line out (green) Line in (blue) Mic (pink) Video To
  • IBM 8480 | Hardware Maintenance Manual - Page 72
    devices are disabled during the power-on self-test (POST). 6 4 2 5 3 1 Mouse connector Your server has one mouse connector that supports a mouse or other pointing mode, the server supports the ECP and EPP modes. 62 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 73
    LED on the rear of the server (see the User's Guide). Configuring the Gigabit Ethernet controller The drivers are provided on the Device Drivers and IBM Enhanced Diagnostics CD. When you connect your server supports optional modes, such as teaming, load balancing, fault tolerance, and virtual LANs
  • IBM 8480 | Hardware Maintenance Manual - Page 74
    during the power-on self support server sound system. Microphone This connector is used to connect a microphone to your server when you want to record sounds on the hard disk drive or use speech recognition software. 64 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 75
    network. Ethernet link status light (green) Ethernet activity light (green) Ethernet port (RJ-45) P- P Serial port (COM) ASM Interconnect port (RJ-14) Error light (amber) P- P Power light (green) External power supply connector (not used) Chapter 4. Installing options 65
  • IBM 8480 | Hardware Maintenance Manual - Page 76
    66 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 77
    / fan sink 71 Hot-swap hard disk drive cage 72 Power supply 73 Rear fan 74 Extender card 75 System board 77 CD-ROM replaceable unit (FRU) procedures are intended for trained servicers who are familiar with IBM xSeries products. See the parts listing in "System" on page 112 to determine
  • IBM 8480 | Hardware Maintenance Manual - Page 78
    2. Turn off the server and peripheral devices and disconnect all power cords and then all server. 6. Pull the bezel up to release the two tabs at the bottom edge of the bezel. Store the bezel in a safe place. 68 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 79
    on page 33. To remove the power button, complete the following steps: 1. Turn off the server, if it is on. 2. Unplug the server. 3. Remove the side cover. the power switch and LED panel cable connector. b. Some cables might have two connectors for you to disconnect. c. See the system service label
  • IBM 8480 | Hardware Maintenance Manual - Page 80
    aperture and remove the power button. Hot-swap server. 3. Remove the front bezel. See "Removing the front bezel" on page 68. 4. Remove the side cover. See "Removing the side cover" on page 40. 5. Remove the support IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 81
    , do the following: 1. Power-off the computer and remove external cables. 2. Remove the cover and support bracket (see "Removing the on page 40 and "Removing the frame-support bracket" on page 41). 3. Disconnect provided with the replacement part, be sure to remove all traces of existing adhesive
  • IBM 8480 | Hardware Maintenance Manual - Page 82
    from the front of the hard disk drive cage. 9. Move the cage slightly in and up until it is free of the chassis and lift it out of the server. Note: Take care not to dislodge the memory when you remove the cage. 72 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 83
    Read "Safety information" on page 119. v Read "System reliability considerations" on page 33. To remove the power supply, do the following: 1. Turn off the server, if it is on. 2. Unplug the server. 3. Remove the cover. See "Removing the side cover" on page 40. 4. Disconnect internal cables from the
  • IBM 8480 | Hardware Maintenance Manual - Page 84
    position at the rear of the server. 9. Guide the rubber extensions through the apertures. 10. Use needle-nosed pliers to pull the extensions through the apertures. Rear Fan Rubber extensions 11. Reconnect cables. 74 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 85
    server be placed on its left side before performing this service procedure. Rotate the feet in toward the server so they do not detach due to the weight of the server server, if it is on. 2. Unplug the server. 3. Remove the side cover. See "Removing the side cover" on page 40. 4. Remove the support
  • IBM 8480 | Hardware Maintenance Manual - Page 86
    extender card screws. 9. Disconnect the extender card connector from the system board edge connector: then, tilt the extender card and remove it from the server. To install an extender card reverse this procedure. 76 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 87
    the system board, you must either update the system with the latest firmware or restore the pre-existing firmware that the customer provides on a diskette or CD image. 4. It is recommended that the server be placed on its left side before performing this service procedure. Rotate the feet in toward
  • IBM 8480 | Hardware Maintenance Manual - Page 88
    page 40. 4. Disconnect the cables. 5. Remove the screws from the CD-ROM drive cage. 6. Gently slide the CD-ROM drive toward the front of the server and lift it out. 78 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 89
    119. v Read "System reliability considerations" on page 33. To remove the diskette drive, complete the following steps: 1. Turn off the server, if it is on. 2. Unplug the server. 3. Remove the side cover. See "Removing the side cover" on page 40. 4. Disconnect the cables. 5. Remove the screws from
  • IBM 8480 | Hardware Maintenance Manual - Page 90
    the bezel-release latch, complete the following steps: 1. Turn off the server, if it is on. 2. Unplug the server. 3. Remove the side cover. See "Removing the side cover" on page it back and away from the server. 80 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 91
    119. v Read "System reliability considerations" on page 33. To remove the top/side cover, complete the following steps: 1. Turn off the server, if it is on. 2. Unplug the server. 3. Remove the side cover. See "Removing the side cover" on page 40. 4. Remove the front bezel. See "Removing the front
  • IBM 8480 | Hardware Maintenance Manual - Page 92
    off the server, if it is on. 2. Unplug the server. 3. Firmly grasp the handle support and slide it away from the front bezel. 4. Lift up on the handle support to remove it from the slots in the top of the chassis. 82 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 93
    119. v Read "System reliability considerations" on page 33. To remove the adapter retainer, complete the following steps: 1. Turn off the server, if it is on. 2. Unplug the server. 3. Remove the side cover. See "Removing the side cover" on page 40. 4. Remove all adapters. See "Installing an adapter
  • IBM 8480 | Hardware Maintenance Manual - Page 94
    84 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 95
    107 Undetermined problems 108 Problem determination tips 109 This index supports xSeries 205 servers. Notes: 1. Check the configuration before you replace a FRU. Configuration problems can cause false errors and symptoms. 2. For IBM devices not supported by this index, refer to the manual for that
  • IBM 8480 | Hardware Maintenance Manual - Page 96
    separated by pauses (intervals without sound). See the examples in the following a field service technician. Beep BIOS EEPROM checksum failed.) 1. Recover BIOS failed.) v DIMM. v Memory adapter 1-3-2 (First 64K RAM IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 97
    should be replaced by a field service technician. Beep/symptom FRU/action server power cord from outlet, wait 30 seconds and retry. 2. System board. 3. Microprocessor. 4. DIMMs. 5. DASD backplane. 6. DASD power cable. 3-3-3 (No operational memory in system.) 1. Install or reseat the memory
  • IBM 8480 | Hardware Maintenance Manual - Page 98
    system board (J10). drive.) 3. Failing drive. SCSI channel A has failed. (This is the SCSI channel for the hot-swap hard disk drives). 4. DASD backplane. 88 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 99
    . Diagnostics panel LED FRU/action SERVICE PROCESSOR BUS LED. 1. Unplug the server for 30 seconds, and then retry. 2. Reflash or update firmware for ISMP, BIOS. 3. System board. POWER SUPPLY 1 LED on. 1. Check the dc good LED on power supply 1. If it is off, replace power supply 1. 2. Power
  • IBM 8480 | Hardware Maintenance Manual - Page 100
    Diagnostic error codes " on page 112 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 001-XXX-000 (Failed core tests) latch assembly. 2. System board. 90 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 101
    S99 (RAID adapter initialization failure.) 1. ServeRAID adapter in slot s is not configured properly. Obtain the basic and extended configuration status and see the ServeRAID Hardware Maintenance Manual for more information. 2. Cable. 3. SCSI backplane. 4. Adapter. 075-XXX-000 (Failed power supply
  • IBM 8480 | Hardware Maintenance Manual - Page 102
    BIOS. 2. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry. 3. Remote Supervisor Adapter. 166-400-000 System Management: Failed 1. Reflash or update firmware board. 92 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 103
    replaced by a field service technician. Error code/symptom FRU/action 201-XXX-0NN (Failed memory test.) 1. DIMM Location BIOS hard disk test) Note: If RAID is configured, the hard disk number refers to the RAID logical array. v Hard disk 1 217-XXX-001 (Failed BIOS hard disk test) Note: If RAID
  • IBM 8480 | Hardware Maintenance Manual - Page 104
    n. (Failed Ethernet test on adapter in PCI slot n.) 2. System board. 415-XXX-000 (Failed Modem test.) 1. Cable. Note: Ensure modem is present and attached to server. 2. Modem. 3. System board. 94 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 105
    that have definite symptoms. If you cannot find the problem in the error symptom charts, go to "Starting the diagnostic programs" on page 26 to test the server. If you have just added new software or a new option and your server is not working, complete the following steps before using the
  • IBM 8480 | Hardware Maintenance Manual - Page 106
    the dc good LED is lit, replace the adapters and devices one at a time until you isolate the problem. 3. Power supply. 4. Power cage assembly, if installed. 5. System board. On On Power is working properly. N/A 96 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 107
    page 112 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 062 (Three consecutive boot board. 164 (Memory configuration changed.) 1. Run the Configuration/Setup Utility program. 2. DIMM. 3. System board. 184 (Power-on password damaged
  • IBM 8480 | Hardware Maintenance Manual - Page 108
    should be replaced by a field service technician. Error code/symptom FRU/ the Configuration/Setup Utility program and diagnostics. 2. Diskette drive. 3. Drive BIOs and run the Configuration/Setup Utility program. 98 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 109
    that a startable operating system is installed. 2. Run diagnostics. 3. Hard disk drive. 4. SCSI backplane. 5. Cable. 6. System board. 5962 (IDE CD-ROM drive configuration error) 1. Run the Configuration/Setup Utility program. 2. CD-ROM drive. 3. CD-ROM power cable. 4. IDE cable. 5. System board
  • IBM 8480 | Hardware Maintenance Manual - Page 110
    Channel Code (z) 1 2 3 4 5 6 7 8 9 A B C Descriptions Channel 1 Channel 2 Channel 1 & 2 Channel 3 Channel 1 & 3 Channel 2 & 3 Channel 1, 2, & 3 Channel 4 Channel 1 & 4 Channel 2 & 4 Channel 1, 2, & 4 Channel 3 & 4 100 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 111
    download jumpers on the controller and try to flash the firmware code to the card. 2. Isolate between SCSI subsystem and controller by disconnecting all hard disk drive cables attached to the suspect card, and reboot. CAUTION: Do not press F5. Doing so will change the server the problem. d.
  • IBM 8480 | Hardware Maintenance Manual - Page 112
    PCI bus interface error) 1. Flash latest level of BIOS code and firmware for controller. 2. If ServeRAID-4x controller, replace controller. 3. If ServeRAID-5i controller, integrated RAID controller on the server. 102 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 113
    replaced by a field service technician. Error code/symptom FRU/action 9003 1. Flash latest level of BIOS code and firmware for controller. 2. Confirm that this controller is a supported option for this system. 3. ServeRAID controller. 4. Integrated RAID controller on the server). 9xxx thru BZxx
  • IBM 8480 | Hardware Maintenance Manual - Page 114
    x. 2. Replace fan x. Fan x fault (level-critical; fan x beyond recommended RPM range) 1. Check connections to fan x. 2. Replace fan x. Fan x outside recommended speed action 1. Replace fan x. 104 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 115
    field service technician. Message Action Power supply x current share fault (level-critical; excessive current demand on power supply x) v Replace power supply x. Power supply x DC good fault v Replace power supply x. (level-critical; power good signal not detected for power supply x) Power
  • IBM 8480 | Hardware Maintenance Manual - Page 116
    specifications; see "Features and specifications" service technician. Message Action Hard drive x removal detected (level-critical; hard drive x has been removed) v Information only, take action as appropriate. 106 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 117
    components should be replaced by a field service technician. Bus fault messages Message Action connector on the PCI riser card. 2. Memory DIMMs. 3. System board. Failure reading 12C power supply (power cage assembly, if installed) (J10). 2. Power cage assembly, if installed. 3. Power supply
  • IBM 8480 | Hardware Maintenance Manual - Page 118
    and replacing that adapter does not correct the problem, suspect the system board. 2. If you suspect a networking problem and all the system tests pass, suspect a network cabling problem external to the system. 108 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 119
    problem determination. If possible, have this information available when requesting assistance from Service Support and Engineering functions. v Machine type and model v Microprocessor or hard disk upgrades v Failure symptom - Do diagnostics models 2. Have the same BIOS level 3. Have the same
  • IBM 8480 | Hardware Maintenance Manual - Page 120
    110 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 121
    Chapter 7. Parts listing Type 8480 This parts listing supports the xSeries 205 Type 8480. 1 19 18 17 16 15 14 2 3 4 5 6 9 10 11 12 13 8 7 © Copyright IBM Corp. 2002 111
  • IBM 8480 | Hardware Maintenance Manual - Page 122
    5 6 6 6 7 8 9 9 10 11 11 12 13 14 14 14 15 16 16 16 16 16 16 16 16 16 17 18 19 System, xSeries 205, Type 8480, Models 13x 22x 23x 2Ax 32x 33x 3Ax 42x 43x 4AG 4Ax 52x 53x 5Ax 62x 63x 6Ax 93x 94x 95x 96x. Chassis (all models) CD-ROM drive, 48X XP, primary (all models) CD-ROM drive, 48X XP, alternate
  • IBM 8480 | Hardware Maintenance Manual - Page 123
    System, xSeries 205, Type 8480, Models 13x 22x 23x 2Ax 32x 33x 3Ax 42x 43x 4AG 4Ax 52x 53x 5Ax 62x 63x Power button kit (all models) Power supply, 330 watt (all models) Power supply, 340 watt (all models) Release bar (all models) System service label (all models) Power Parts listing Type 8480 113
  • IBM 8480 | Hardware Maintenance Manual - Page 124
    set should have the appropriate safety approvals for the country in which the equipment will be installed. IBM power cords for a specific country or region are usually available only in that country or region. 114 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 125
    IBM power cord part number 13F9940 13F9979 13F9997 14F0015 14F0033 14F0051 14F0069 14F0087 1838574 6952301 Used in these countries and regions Argentina, Australia, China (PRC), New Zealand, Papua New Trinidad (West Indies), United States of America, Venezuela Chapter 7. Parts listing Type 8480 115
  • IBM 8480 | Hardware Maintenance Manual - Page 126
    116 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 127
    instructions for using the diagnostic programs. The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software. IBM maintains pages on the World Wide Web where you can get the latest technical information and download
  • IBM 8480 | Hardware Maintenance Manual - Page 128
    for support telephone numbers. In the U.S. and Canada, hardware service and support is available 24 hours a day, 7 days a week. In the U.K., these services are available Monday through Friday, from 9 a.m. to 6 p.m. 118 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 129
    problems. They are written with the assumption that you have model-specific training on all computers, or that are familiar with the computers, functions, terminology, and service information provided in this manual other parts in a safe place, away from all personnel, while you are servicing the
  • IBM 8480 | Hardware Maintenance Manual - Page 130
    ; these instructions are in the safety sections of maintenance information. Use extreme care when measuring high voltages. v Regularly inspect and maintain your electrical hand tools for safe operational condition. 120 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 131
    Do not service the following parts with the power on when they are removed from their normal operating places in a machine: - Power supply units - Pumps safety hazards due to attachment of non-IBM features or options not covered by this inspection guide. If any unsafe conditions are present,
  • IBM 8480 | Hardware Maintenance Manual - Page 132
    the charge so that the server, the part, the work mat, and the person handling the part are all at the same charge. Notes: 1. Use product-specific ESD procedures when they exceed verified by a certified electrician. 122 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 133
    IBM instructions. Statement 1 DANGER Electrical current from power power power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed power cords to outlet. 5. Turn device ON. To Disconnect 1. Turn everything OFF. 2. First, remove power
  • IBM 8480 | Hardware Maintenance Manual - Page 134
    product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or adjustments or performance of safe practices when lifting. ≥55 kg (121.2 lbs) 124 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 135
    device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. 2 1 Statement 10
  • IBM 8480 | Hardware Maintenance Manual - Page 136
    Importante: Todas as instruções de cuidado e perigo da IBM documentation começam com um número. Este número é utilizado para 3. Remova os cabos de sinal dos conectores. 4. Remova todos os cabos dos dispositivos. 126 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 137
    (011) 889-8986, para obter informações sobre como enviar a bateria pelo correio para a IBM. Instrução 3 PRECAUCIÓN: Quando produtos a laser (unidades de CD-ROM, unidades de DVD, dispositivos nu ou com instrumentos íticos, e evite exposição direta ao raio. Appendix B. Related service information 127
  • IBM 8480 | Hardware Maintenance Manual - Page 138
    da fonte de energia elétrica. 2 1 Instrução 10 CUIDADO: Não coloque nenhum objeto com peso superior a 82 kg (180 lbs.) sobre dispositivos montados em rack. 128 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 139
    Appendix B. Related service information 129
  • IBM 8480 | Hardware Maintenance Manual - Page 140
    130 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 141
    Appendix B. Related service information 131
  • IBM 8480 | Hardware Maintenance Manual - Page 142
    132 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 143
    Appendix B. Related service information 133
  • IBM 8480 | Hardware Maintenance Manual - Page 144
    134 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 145
    Appendix B. Related service information 135
  • IBM 8480 | Hardware Maintenance Manual - Page 146
    aux réseaux, aux systèmes de télécommunication et aux modems (sauf instruction contraire mentionnée dans les procédures d'installation et de configuration). v connecteurs. 4. Débranchez tous les câbles des unités. 136 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 147
    la pile au lithium usagée par une pile de référence identique exclusivement - voir la référence IBM - ou par une pile équivalente recommandée par le fabricant. Si votre système est doté l'aide d'instruments optiques. évitez une exposition directe au rayon. Appendix B. Related service information 137
  • IBM 8480 | Hardware Maintenance Manual - Page 148
    de prise de courant. 2 1 Notice n° 10 ATTENTION: Ne posez pas d'objet dont le poids dépasse 82 kg sur les unités montées en armoire. 138 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 149
    Wichtig: Alle Sicherheitshinweise in dieser IBM documentation beginnen mit einer Nummer. Diese Nummer verweist auf einen englischen Sicherheitshinweis mit von Steckdose lösen. 3. Signalkabel von Anschlußbuchsen lösen. 4. Alle Kabel von Einheiten lösen. Appendix B. Related service information 139
  • IBM 8480 | Hardware Maintenance Manual - Page 150
    : Eine verbrauchte Batterie nur durch eine Batterie mit der IBM Teilenummer 33F8354 oder durch eine vom Hersteller empfohlene Batterie ersetzen mit optischen Instrumenten betrachten und den Strahlungsbereich meiden. 140 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 151
    . Um die gesamte Stromversorgung des Servers auszuschalten, muß sichergestellt werden, daß alle Netzkabel aus den Netzsteckdosen herausgezogen wurden. 2 1 Hinweis 10 ACHTUNG: Keine Gegenstände, die mehr als 82 kg wiegen, auf Rack-Einheiten ablegen. Appendix B. Related service information 141
  • IBM 8480 | Hardware Maintenance Manual - Page 152
    avvisi di attenzione e di pericolo riportati nella pubblicazione IBM documentation iniziano con un numero. Questo numero viene utilizzato i cavi di segnale dai connettori. 4. Rimuovere tutti i cavi dalle unità. 142 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 153
    la batteria al litio, utilizzare solo una batteria IBM con numero parte 33F8354 o batterie dello stesso tipo o di tipo o l'esecuzione di procedure non descritti nel presente manuale possono provocare l'esposizione a radiazioni pericolose. PERICOLO Alcuni Appendix B. Related service information 143
  • IBM 8480 | Hardware Maintenance Manual - Page 154
    che tutti i cavi di alimentazione siano scollegati dalla sorgente di alimentazione. 2 1 Avviso 10 ATTENZIONE: Non poggiare oggetti che pesano più di 82 kg sulla parte superiore delle unità montate in rack. 144 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 155
    Appendix B. Related service information 145
  • IBM 8480 | Hardware Maintenance Manual - Page 156
    146 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 157
    Appendix B. Related service information 147
  • IBM 8480 | Hardware Maintenance Manual - Page 158
    148 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 159
    Appendix B. Related service information 149
  • IBM 8480 | Hardware Maintenance Manual - Page 160
    150 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 161
    Importante: Todas las declaraciones de precauciín de esta IBM documentation empiezan con un número. Dicho número se emplea para establecer una referencia cruzada 4. Retire los cables de los dispositivos. toma de alimentaciín. 5. ENCIENDA el dispositivo. Appendix B. Related service information 151
  • IBM 8480 | Hardware Maintenance Manual - Page 162
    sustituir la batería de litio, utilice únicamente el número de pieza 33F8354 de IBM o cualquier tipo de batería equivalente que recomiende el fabricante. Si el sistema ípticos; evite la exposiciín directa al rayo. 152 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 163
    de alimentaciín. 2 1 Declaración 10 PRECAUCIÓN: No coloque ningún objeto que pese más de 82 kg (180 libras) encima de los dispositivos montados en bastidor. Appendix B. Related service information 153
  • IBM 8480 | Hardware Maintenance Manual - Page 164
    154 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 165
    operation of any non-IBM product, program, or service. IBM may have patents or be incorporated in new editions of the publication. IBM may make part of the materials for this IBM product, and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply
  • IBM 8480 | Hardware Maintenance Manual - Page 166
    Memory Active PCI Active PCI-X Alert on LAN C2T Interconnect Chipkill EtherJet e-business logo Eserver FlashCopy IBM Other company, product, or service names may be trademarks or service marks of others. Important notes IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 167
    country-specific instructions, refer to the following Web site: http://www.ibm.com/ibm/environment/products/prp.shtml. This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery. Consult your user manual or service manual for specific battery
  • IBM 8480 | Hardware Maintenance Manual - Page 168
    ICES-003. Avis de conformité à la réglementation d'Industrie Canada Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. 158 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 169
    States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure product, including the fitting of non-IBM option cards. This product has been IBM power cords for a specific country or region are usually available only in that country or region. IBM power cord part
  • IBM 8480 | Hardware Maintenance Manual - Page 170
    IBM power cord part number 13F9979 (Republic of), Monaco, Mongolia, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Reunion, Romania, Argentina, Paraguay, Uruguay India Brazil 160 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 171
    IBM power cord part number 6952300 Used in these countries and regions Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Caicos Islands, Canada, Cayman Islands, Colombia, Costa Rica,
  • IBM 8480 | Hardware Maintenance Manual - Page 172
    162 IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
  • IBM 8480 | Hardware Maintenance Manual - Page 173
  • IBM 8480 | Hardware Maintenance Manual - Page 174
    Part Number: 59P2108 (1P) P/N: 59P2108
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

IBM
xSeries
205
Type
8480
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
E