IBM 8480 Hardware Maintenance Manual - Page 43

Installing, options

Page 43 highlights

Chapter 4. Installing options This section provides instructions for installing options in an IBM xSeries Eserver 205 Type 8480. System reliability considerations To help ensure proper system cooling and system reliability, make sure that: v Each of the drive bays has a drive or a filler panel and electromagnetic compatibility (EMC) shield installed. v There is adequate space around the server to allow the server cooling system to work properly. Leave approximately 51 mm (2 in.) of open space around the front and rear of the server. Do not place objects in front of the fans. v You have followed the instructions for cabling provided with optional adapters. v You have replaced a failed fan as soon as possible. Major components of the IBM xSeries 205 Type 8480 Eserver The following illustration shows the locations of major components in the IBM xSeries 205 Type 8480 server. Eserver Note: The illustrations in this document might look slightly different from your hardware. Microprocessor Rear adapterretaining bracket Memory modules PCI extender board EMC shields Filler panels Drive cage Front adaptersupport bracket Frame-support bracket Cover © Copyright IBM Corp. 2002 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

Chapter
4.
Installing
options
This
section
provides
instructions
for
installing
options
in
an
IBM
Eserver
xSeries
205
Type
8480.
System
reliability
considerations
To
help
ensure
proper
system
cooling
and
system
reliability,
make
sure
that:
v
Each
of
the
drive
bays
has
a
drive
or
a
filler
panel
and
electromagnetic
compatibility
(EMC)
shield
installed.
v
There
is
adequate
space
around
the
server
to
allow
the
server
cooling
system
to
work
properly.
Leave
approximately
51
mm
(2
in.)
of
open
space
around
the
front
and
rear
of
the
server.
Do
not
place
objects
in
front
of
the
fans.
v
You
have
followed
the
instructions
for
cabling
provided
with
optional
adapters.
v
You
have
replaced
a
failed
fan
as
soon
as
possible.
Major
components
of
the
IBM
Eserver
xSeries
205
Type
8480
The
following
illustration
shows
the
locations
of
major
components
in
the
IBM
Eserver
xSeries
205
Type
8480
server.
Note:
The
illustrations
in
this
document
might
look
slightly
different
from
your
hardware.
Rear adapter-
retaining bracket
Front adapter-
support bracket
Drive cage
Microprocessor
Memory modules
Cover
Frame-support bracket
PCI extender
board
EMC shields
Filler
panels
©
Copyright
IBM
Corp.
2002
33