IBM 865951Y Hardware Maintenance Manual - Page 170

FRU/Action, System Board

Page 170 highlights

Error Code/Symptom 289 (DIMM has been disabled by the user or system) 301 (Keyboard or keyboard controller error) 303 (Keyboard controller error) 602 (Invalid diskette boot record) 604 (Diskette drive error) 605 (Unlock failure) 662 (Diskette drive configuration error) 762 (Coprocessor configuration error) 962 (Parallel port error) 11XX (System board serial port 1 or 2 error) FRU/Action 1. Run Configuration/Setup, if disabled by user 2. Ensure if a DIMM was added/changed that the power was disconnected. 3. Disable DIMM, if not disabled by user. 1. Keyboard 2. System Board 1. Keyboard 2. System Board 1. Diskette 2. Cable 3. Diskette Drive 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board 1. Diskette Drive 2. Drive Cable 3. System Board 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board 1. Run Configuration/Setup 2. Battery 3. Processor 1. Disconnect external cable on parallel port. 2. Run Configuration/Setup 3. System Board 1. Disconnect external cable on serial port. 2. Run Configuration/Setup 3. System Board 162 Netfinity Server HMM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220

Error Code/Symptom
FRU/Action
289
(DIMM has been disabled
by the user or system)
1.
Run
Configuration/Setup,
if disabled by user
2.
Ensure if a DIMM was
added/changed that
the power was
disconnected.
3.
Disable DIMM, if not
disabled by user.
301
(Keyboard or keyboard
controller error)
1.
Keyboard
2.
System Board
303
(Keyboard controller error)
1.
Keyboard
2.
System Board
602
(Invalid diskette boot record)
1.
Diskette
2.
Cable
3.
Diskette Drive
604
(Diskette drive error)
1.
Run
Configuration/Setup
and Diagnostics
2.
Diskette Drive
3.
Drive Cable
4.
System Board
605
(Unlock failure)
1.
Diskette Drive
2.
Drive Cable
3.
System Board
662
(Diskette drive configuration
error)
1.
Run
Configuration/Setup
and Diagnostics
2.
Diskette Drive
3.
Drive Cable
4.
System Board
762
(Coprocessor configuration
error)
1.
Run
Configuration/Setup
2.
Battery
3.
Processor
962
(Parallel port error)
1.
Disconnect external
cable on parallel port.
2.
Run
Configuration/Setup
3.
System Board
11XX
(System board serial port 1
or 2 error)
1.
Disconnect external
cable on serial port.
2.
Run
Configuration/Setup
3.
System Board
162