IBM IC35L036UWDY10 Hard Drive Specifications - Page 227
SCSI Bus Reset and TARGET RESET Message, 16.4 Self-initiated Reset
UPC - 000004119524
View all IBM IC35L036UWDY10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 227 highlights
11.16.3 SCSI Bus Reset and TARGET RESET Message These two reset conditions cause the following to be performed. ! If reset goes active while the power-up sequence is in progress, the power-up sequence is started over. ! If the Auto Spin up is enabled and the bring-up operation has not been completed, the bring-up operation will be re-attempted from the beginning. Note: The bring-up operation, having already completed, is not rerun. ! If reset occurs while a physical sector is being written, the write operation is disabled after the current physical sector is written. Data is not lost as long as power stays valid until the physical sector being written is completed. 11.16.4 Self-initiated Reset When the microcode detects an internal logic error, it takes a special bring-up sequence to save the information necessary to analyze the error. After saving the information, the normal bring-up sequence is taken to start over. . Ultrastar 146Z10 hard disk drive specifications 211