Mounting positions and tappings, Drive mounting
![]() |
UPC - 000004119524
View all IBM IC35L036UWDY10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
7.7.4 Mounting positions and tappings (6X) 6-32 UNC1 (4X) 6-32 UNC 2 (2X) 60 +/- 0.2 41.28 +/- 0.5 44.45 +/- 0.2 (2X) (2X) 41.6 +/- 0.2 (2X) (2X) 28.5 +/- 0.5 (6X) 6.35 +/- 0.2 (2X) 95.25 +/- 0.2 RIGHT REAR RECOMMENDED TORQUE 0.6 - 1.0 Nm 1 MAX ALLOWABLE PENETRATION OF NOTED SCREW TO BE 4.5 mm . 2 MAX ALLOWABLE PENETRATION OF NOTED SCREW TO BE 4.0 mm . SCREW 6-32 UNC THICKNESS OF BRACKET 12 Figure 42. Mounting positions and tappings Drive mounting The drive will operate in all axes (six directions). Performance and error rate will stay within specification limits if the drive is operated in the other orientations from which it was formatted. The recommended mounting screw torque is 0.6 - 1.0 Nm (6 - 10 Kgf.cm). The recommended mounting screw depth is 4 mm maximum for bottom and 4.5 mm maximum for horizontal mounting. To avoid performance degradation, mount the drive in the system securely enough to prevent excessive motion or vibration of the drive at seek operation or spindle rotation, using appropriate screws or equivalent mounting hardwares. Consult with the issuer of this specification for actual application if necessary. Ultrastar 146Z10 hard disk drive specifications 39