IBM IC35L036UWDY10 Hard Drive Specifications - Page 46
environment, 3.1 Corrosion test
UPC - 000004119524
View all IBM IC35L036UWDY10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
7.3 Environment Operating conditions Temperature Relative Humidity Maximum Wet Bulb Temperature Maximum Temperature Gradient Altitude Non-operating conditions Temperature Relative Humidity Maximum Wet Bulb Temperature Maximum Temperature Gradient Altitude 5 to 55°C (See note) 8 to 90%, non-condensing 29.4°C, non-condensing 15°C/Hour -300 to 3048 m -40 to 65°C 5 to 95%, non-condensing 35°C, non-condensing 15°C/Hour -300 to 12,000 m Figure 26. Operating and non-operating conditions NOTE: The system must provide sufficient ventilation to maintain a surface temperature not to exceed 60 °C at the center of the drive top cover. Non-condensing conditions should be maintained at all times. Maximum storage period within shipping package is one year. Relative Humidity (%) 100 90 36'C/95% 80 31'C/90% Wet Bulb 35C 70 Wet Bulb 29.4C 60 50 Shipping/Storage 40 Operating 30 20 65'C/14% 55'C/15% 10 0 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 Temperature (C) Figure 27. Temperature and relative humidity 7.3.1 Corrosion test The hard disk drive shows no signs of corrosion inside or outside of the hard disk assembly and remains functional after being exposed to a temperature of 50°C and relative humidity of 90% for seven days. Ultrastar 146Z10 hard disk drive specifications 30