Log Sense LBA of First Failure
![]() |
UPC - 000004119524
View all IBM IC35L036UWDY10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
8.7.10 Log Sense Page 10 This page contains Self-test results. Byte 0 1 2-3 4- Bit 7 6 5 4 3 2 1 0 Reserved Page code = 10h Reserved PageLength = 190h Self-test results log parameters First self-test results log parameter -403h Last self-test results log parameter The results of the twenty most recent self-tests are stored in this Log page. The following table describes the self-test results log parameter structure. Byte 0-1 2 3 4 5 6-7 8-15 16 17 18 19 Bit 7 6 5 4 3 2 1 0 Parameter code DU =0 DS TSD ETC = =0 =0 0 TMC = 0 LBIN LP =1 =1 Parameter Length = 10h Function Code RSVD Self-Test Results Value Extended Segment Number Timestamp LBA of First Failure Reserved Sense Key Additional Sense Code Additional Sense Code Qualifier Vendor specific Figure 76. Log Sense Page 10, Self-Test Results ! Parameter Code identifies the log parameter for the log page. The parameter Code field for the results of the most recent test will be 0001h. The parameter for the next most recent will be 0002h. ! Function Code contains the content of the Function Code field in the SEND DIAGNOSTIC command that initiated this self-test. ! Self-Test Results Value is described in the table below. Ultrastar 146Z10 hard disk drive specifications 77