Intel S1200RP Technical Product Specification - Page 32
Power Supply Module Efficiency, Power Cord Specification Requirements, AC Input Requirement
View all Intel S1200RP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Power Subsystem Intel® Server System R1000RP Family TPS 3.2.3 Power Supply Module Efficiency The following table provides the required minimum efficiency level at various loading conditions. These are provided at three different load levels: 100%, 50%, and 20%. Table 15. 450WAC Power Supply Efficiency Loading 100% of maximum 50% of maximum 20% of maximum Minimum Efficiency 88% 92% 88% 3.2.4 Power Cord Specification Requirements The power cords used must meet the specification requirements listed in the following table. Table 16. AC Power Cord Specifications Cable Type Wire Size Temperature Rating Amperage Rating Voltage Rating SJT 16 AWG 105ºC 13 A 125 V Figure 20. AC Power Cord 3.2.5 AC Input Requirement 3.2.5.1 Power Factor The power supply must meet the power factor requirements stated in the Energy Star® Program Requirements for Computer Servers. These requirements are stated below. Output power Power factor 20% load 0.8 50% load 0.9 100% load 0.95 Tested at 230VAC, 50Hz and 60Hz; and 115VAC, 60Hz. 3.2.5.2 AC Input Voltage Specification The power supply must operate within all specified limits over the following input voltage range. Harmonic distortion of up to 10% of the rated line voltage must not cause the power supply to go out of specified limits. Application of an input voltage below 85VAC should not cause damage to the power supply, including a blown fuse. 22 Intel order number: G91532-003 Revision 1.2