Intel SC450NX Product Guide - Page 177

B Regulatory Specifications, Regulatory and Environmental Specifications, Environmental Specifications

Page 177 highlights

B Regulatory Specifications Regulatory and Environmental Specifications Environmental Specifications Table 56. Environmental Specifications Temperature Nonoperating Operating -40° to 70 °C (-55° to 150 °F) 10° to 35 °C (41° to 95 °F); derated 0.5 °C for every 1000 ft (305 m) Altitude to 10,000 ft max; maximum rate of change = 10°C per hour Humidity Nonoperating Operating wet bulb 95% relative humidity (noncondensing) at 30 °C (86 °F) Not to exceed 33 °C (91.4 °F) (with diskette drive or hard disk drive) Shock Operating Packaged 2.0 g, 11 msec, 1/2 sine Operational after 30-inch free fall (cosmetic damage might occur) Acoustic noise < 47 dBA with one power supply at 28 °C +/- 2 °C < 50 dBA with two power supplies at 28 °C +/- 2 °C < 55 dBA with three power supplies at 28 °C +/- 2 °C Electrostatic discharge (ESD) Tested to 20 kilovolts (kV) per Intel environmental test specifications; no component damage AC Input Power 100-120 V∼ 200-240 V∼ 100-120 V∼, 7.6 A, 50/60 Hz 200-240 V∼, 3.8 A, 50/60 Hz Declaration of the Manufacturer or Importer We hereby certify that this product is in compliance with European Union EMC Directive 89/336/EEC, using standards EN55022 (Class B) and EN50082-1 and Low Voltage Directive 73/23/EEC, Standard EN60950. Safety Compliance USA: Canada: Europe: International: Australian / New Zealand UL 1950 - CSA 950-95, 3rd Edition UL certified to CSA 950-95 for Canada (product bears the single UL mark for U.S. and Canada) German GS Mark - ERG to EN60950 2nd Edition, with amendments NEMKO to IEC950 2nd Edition + Amd 1-4 NEMKO - EN60 950 2nd Edition + Amd 1-4 NEMKO - EMKO-TSE (74-SEC) 207/94 AS/NZ 3548, Class B limits (CISPR 22) AS/NZ 3260 (IEC 950 including national AU deviations) 177

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

177
B
Regulatory Specifications
Regulatory and Environmental Specifications
Environmental Specifications
Table 56.
Environmental Specifications
Temperature
Nonoperating
Operating
–40° to 70 °C (–55° to 150 °F)
10° to 35 °C (41° to 95 °F); derated 0.5 °C for every 1000 ft (305 m)
Altitude to 10,000 ft max; maximum rate of change = 10°C per hour
Humidity
Nonoperating
Operating wet
bulb
95% relative humidity (noncondensing) at 30 °C (86 °F)
Not to exceed 33 °C (91.4 °F) (with diskette drive or hard disk drive)
Shock
Operating
Packaged
2.0 g, 11 msec, 1/2 sine
Operational after 30-inch free fall (cosmetic damage might occur)
Acoustic noise
< 47 dBA with one power supply at 28 °C +/- 2 °C
< 50 dBA with two power supplies at 28 °C +/- 2 °C
< 55 dBA with three power supplies at 28 °C +/- 2 °C
Electrostatic
discharge (ESD)
Tested to 20 kilovolts (kV) per Intel environmental test specifications; no
component damage
AC Input Power
100-120 V
200-240 V
100-120 V
, 7.6 A, 50/60 Hz
200-240 V
, 3.8 A, 50/60 Hz
Declaration of the Manufacturer or Importer
We hereby certify that this product is in compliance with European Union EMC Directive
89/336/EEC, using standards EN55022 (Class B) and EN50082-1 and Low Voltage Directive
73/23/EEC, Standard EN60950.
Safety Compliance
USA:
UL 1950 - CSA 950-95, 3rd Edition
Canada:
UL certified
to CSA 950-95 for Canada (product bears the single UL mark for
U.S. and Canada)
Europe:
German GS Mark - ERG to EN60950 2nd Edition, with amendments
International:
NEMKO to IEC950 2
nd
Edition + Amd 1-4
NEMKO - EN60 950 2
nd
Edition + Amd 1-4
NEMKO - EMKO-TSE (74-SEC) 207/94
Australian /
New Zealand
AS/NZ 3548, Class B limits (CISPR 22)
AS/NZ 3260 (IEC 950 including national AU deviations)