Intel SC450NX Product Guide - Page 43
Boot Menu, Console Redirection Submenu
View all Intel SC450NX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Console Redirection Submenu Table 19. Console Redirection Submenu Feature Choices Description COM Port Address IRQ # Baud Rate Flow Control Disabled 3F8 2F8 3E8 None, 3, or 4 9600 19.2k 38.4k 115.2k No flow control CTS/RTS XON/XOFF CTS/RTS + CD When enabled, console redirection uses the I/O port specified. When disabled, console redirection is completely disabled. When console redirection is enabled, this displays the IRQ assigned per the address chosen in the COM Port Address field. When console redirection is enabled, use the baud rate specified. When the Emergency Management Port (EMP) shares the COM port as console redirection, the baud rate must be set to 19.2k to match EMP baud rate, unless the autobaud feature is used. None disallows flow control. CTS/RTS is hardware flow control. XON/XOFF is software flow control. CTS/RTS +CD is hardware plus carrier-detect flow control. Boot Menu You can make the following selections on the Boot Menu itself. Table 20. Boot Menu Feature Floppy Check Multi-boot Support Boot Device Priority Hard Drive Choices Disabled Enabled Disabled Enabled N/A N/A Description If Enabled, system verifies diskette type on boot. Disabled results in a faster boot. Enable this option only if the total number of hard drives is less than eight. Enters submenu. Enters submenu. Removable Devices N/A Enters submenu. Maximum Number of I2O Drives 1 4 Selects the maximum number of I2O drives assigned a DOS drive letter. Message Timeout Multiplier 1, 2, 8, 10, All timeout values are multiplied by this number. 50, 100, 1000 43