Intermec CS40 CS40 Mobile Computer User's Manual - Page 123

Default Configuration, Data Collection Settings

Page 123 highlights

Appendix A - Specifications and Default Settings EA11 Typical Reading Distances Symbology Code 39 UPC/EAN 100% Data Matrix PDF417 Density 0.125 mm (5 mil) 0.20 mm (8 mil) 0.25 mm (10 mil) 0.50 mm (20 mil) 1.0 mm (40 mil) 0.33 mm (13.0 mil) 0.191 mm (7.5 mil) 0.254 mm (10 mil) 0.381 mm (15 mil) 0.168 mm (6.6 mil) 0.254 mm (10 mil) 0.381 mm (15 mil) Minimum Distance 7.2 cm (2.8 in) 3.8 cm (1.5 in) 3.4 cm (1.3 in) 5.0 cm (2.0 in) 8.0 cm (3.1 in) 5 cm (2 in) 6.3 cm (2.5 in) 4.8 cm (1.9 in) * 6.25 cm (2.46 in) 4.5 cm (1.8 in) 4 cm (1.6 in) Maximum Distance 13.1 cm (5.1 in) 22.5 cm (8.8 in) 27 cm (10.5 in) 44 cm (17.2 in) 83 cm (32.4 in) 32.0 cm (12.5 in) 17.3 cm (6.7 in) 22 cm (8.6 in) 29 cm (11.3 in) 15.4 cm (6 in) 23 cm (9 in) 37 cm (14.4 in) Default Configuration The following tables list the default values of the configuration settings supported on the mobile computer. If you restore the mobile computer to factory default settings, the mobile computer uses these values. The settings are grouped by function and reflect the organization of Intermec Settings. For detailed information on most of the commands, see the Intermec Settings Command Reference Manual. Data Collection Settings Use data collection settings to configure the imager and to configure the bar codes that you want the imager to be able to read. Data Collection Settings Data Collection Setting Enable Scanner Port BT-Configure On Connect Default Value On Overwrite with computer settings CS40 Mobile Computer User's Manual 111

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

Appendix A — Specifications and Default Settings
CS40 Mobile Computer User’s Manual
111
EA11 Typical Reading Distances
Default Configuration
The following tables list the default values of the configuration
settings supported on the mobile computer. If you restore the mobile
computer to factory default settings, the mobile computer uses these
values.
The settings are grouped by function and reflect the organization of
Intermec Settings. For detailed information on most of the
commands, see the
Intermec Settings Command Reference Manual
.
Data Collection Settings
Use data collection settings to configure the imager and to configure
the bar codes that you want the imager to be able to read.
Data Collection Settings
Symbology
Density
Minimum Distance
Maximum Distance
Code 39
0.125 mm (5 mil)
0.20 mm (8 mil)
0.25 mm (10 mil)
0.50 mm (20 mil)
1.0 mm (40 mil)
7.2 cm (2.8 in)
3.8 cm (1.5 in)
3.4 cm (1.3 in)
5.0 cm (2.0 in)
8.0 cm (3.1 in)
13.1 cm (5.1 in)
22.5 cm (8.8 in)
27 cm (10.5 in)
44 cm (17.2 in)
83 cm (32.4 in)
UPC/EAN 100%
0.33 mm (13.0 mil)
5 cm (2 in)
32.0 cm (12.5 in)
Data Matrix
0.191 mm (7.5 mil)
0.254 mm (10 mil)
0.381 mm (15 mil)
6.3 cm (2.5 in)
4.8 cm (1.9 in)
*
17.3 cm (6.7 in)
22 cm (8.6 in)
29 cm (11.3 in)
PDF417
0.168 mm (6.6 mil)
0.254 mm (10 mil)
0.381 mm (15 mil)
6.25 cm (2.46 in)
4.5 cm (1.8 in)
4 cm (1.6 in)
15.4 cm (6 in)
23 cm (9 in)
37 cm (14.4 in)
Data Collection Setting
Default Value
Enable Scanner Port
On
BT-Configure On Connect
Overwrite with computer
settings