Intermec CS40 CS40 Mobile Computer User's Manual - Page 51

Using the Imager, CS40 Mobile Computer User's Manual, Field Name, Valid Values

Page 51 highlights

Field Name Lighting Correction allowChanges lightingCorrection Noise Reduction allowChanges noiseReduction Image Rotation allowChanges imageRotation Subsampling allowChanges subSampling Storage Settings allowChanges Image Location allowChanges imageLocation File Name allowChanges Valid Values Description Chapter 4 - Using the Imager True or false True or false Default is true. When set to false, user cannot change the lighting correction setting. Default is true. If no value is provided, the application cannot change the lighting correction value. True or false 0 to 9 Default is true. When set to false, user cannot change the noise reduction setting. Default is no value. If no value is provided, the application does not change the noise reduction setting. True or false None, 90, 180, 270 Default is true. When set to false, user cannot change the rotation setting. Default is no value. If no value is provided, the application does not change the rotation value. True or false None, 1:2, 1:3, 1:4, 1:5, 1:6, 1:7, 1:8 Default is true. When set to false, user cannot change the subsampling rate. Default is no value. If no value is provided, the application does not change the subsampling rate. True or false Default is false. If set to true, user can change settings in the Storage tab. True or false File path Default is false. If set to true, user can change the directory where saved images are stored. Default is no value. If no value is provided, the application does not change the directory where saved images are stored (My Documents\ ImageCapture). True or false Default is false. When set to true, user can change the filename template setting. CS40 Mobile Computer User's Manual 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

Chapter 4 — Using the Imager
CS40 Mobile Computer User’s Manual
39
Lighting Correction
allowChanges
True or false
Default is true. When set to false, user cannot change
the lighting correction setting.
lightingCorrection
True or false
Default is true. If no value is provided, the
application cannot change the lighting correction
value.
Noise Reduction
allowChanges
True or false
Default is true. When set to false, user cannot change
the noise reduction setting.
noiseReduction
0 to 9
Default is no value. If no value is provided, the
application does not change the noise reduction
setting.
Image Rotation
allowChanges
True or false
Default is true. When set to false, user cannot change
the rotation setting.
imageRotation
None, 90, 180,
270
Default is no value. If no value is provided, the
application does not change the rotation value.
Subsampling
allowChanges
True or false
Default is true. When set to false, user cannot change
the subsampling rate.
subSampling
None, 1:2, 1:3,
1:4, 1:5, 1:6, 1:7,
1:8
Default is no value. If no value is provided, the
application does not change the subsampling rate.
Storage Settings
allowChanges
True or false
Default is false. If set to true, user can change
settings in the Storage tab.
Image Location
allowChanges
True or false
Default is false. If set to true, user can change the
directory where saved images are stored.
imageLocation
File path
Default is no value. If no value is provided, the
application does not change the directory where
saved images are stored (My Documents\
ImageCapture).
File Name
allowChanges
True or false
Default is false. When set to true, user can change the
filename template setting.
Field Name
Valid Values
Description