Konica Minolta Kodak Ngenuity 9150 User Guide - Page 39
Maintenance button, Test Patch Reader
View all Konica Minolta Kodak Ngenuity 9150 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Maintenance button When you click the Maintenance button on the Ngenuity Operator Utility main screen, the Maintenance screen will be displayed. This screen provides scanner statistics for total hours, total pages fed and total pages scanned, and also allows you to configure reminders for required maintenance tasks to ensure optimal performance. Scanner Statistics - provides statistics for Total On Time (awake and sleeping), Total Pages (fed) and total Scanned Pages. These totals are updated every 2 seconds. Configuration Maintenance Reminders - allows you to set the interval values for triggering the reminders that are visible in the Maintenance section of the Home screen. Intervals can be set for cleaning the feed rollers (pick, drive and separation rollers), the transport rollers, the optics and to replace the feed rollers (pick, drive and separation rollers). These reminders can also be individually enabled and disabled. To enable and adjust a maintenance reminder, click the check box next to the corresponding component and use the up/down arrows in the Page Interval column to change the value. Click Save to save your changes or Restore to reset the values to the previously saved settings The available interval settings and their defaults are: Reminder Clean Feed Rollers (pick, drive and separation rollers) Clean Transport Rollers Clean Optics (camera covers, imaging guides, sensors) Replace Feed Rollers (pick, drive and separation rollers) Range 1K - 50K 5K - 100K 5K - 150K 100K - 900K Default 10K 50K 50K 600K Maintenance Operations - provides access to additional maintenance and troubleshooting operations. Test Patch Reader - launches the patch reader test wizard, which allows you to feed patch code sheets and determine if the patch patterns are being accurately recognized by the scanner. A-61662 October 2011 4-19