Konica Minolta bizhub C280 Service Manual - Page 101
remove the two connector protective
View all Konica Minolta bizhub C280 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
bizhub C360/C280/C220 MAINTENANCE 4. PERIODICAL MAINTENANCE PROCEDURE Field Service Ver. 1.0 Jul. 2009 3. Remove three screws [1], and [2] remove right door hinge cover [2]. [1] A0EDF2C008DA 4. Open the right door and the regist unit. [1] 5. Remove the screw [1] each, and remove the two connector protective covers [2]. [2] [1] [2] [1] A0EDF2C036DA 6. Remove the harnesses from the wire saddle [1]. 7. Disconnect four connectors [2]. [2] A0EDF2C037DA 46
4. PERIODICAL MAINTENANCE PROCEDURE
Field Service
V
er. 1.0 Jul. 2009
46
bizhub C360/C280/C220
MAINTENANCE
3.
Remove three screws [1], and
remove right door hinge cover [2].
4.
Open the right door and the regist unit.
5.
Remove the screw [1] each, and
remove the two connector protective
covers [2].
6.
Remove the harnesses from the wire
saddle [1].
7.
Disconnect four connectors [2].
A0EDF2C008DA
[1]
[2]
A0EDF2C036DA
[1]
[1]
[2]
A0EDF2C037DA
[1]
[2]
[2]