Konica Minolta bizhub C280 Service Manual - Page 98
Replacing the manual bypass tray separation roller assy, Periodically replacing parts/cycle,
View all Konica Minolta bizhub C280 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
bizhub C360/C280/C220 MAINTENANCE Field Service Ver. 1.0 Jul. 2009 4. PERIODICAL MAINTENANCE PROCEDURE 7. To reinstall, reverse the order of removal. 8. Replace the manual bypass tray separation roller assy. See P.43 9. Select [Service Mode] → [Counter] → [Life] and clear the count of [Manual Tray]. See P.443 4.9.6 Replacing the manual bypass tray separation roller assy A. Periodically replacing parts/cycle • Manual bypass tray separation roller assy: Every 200,000 counts B. Procedure 1. Remove the rear right cover. See P.54 [1] 2. Disconnect two connectors [1]. A0EDF2C007DA [2] 3. Remove three screws [1], and remove right door hinge cover [2]. [1] 4. Open the right door. A0EDF2C008DA 43
Field Service
V
er. 1.0 Jul. 2009
4. PERIODICAL MAINTENANCE PROCEDURE
43
bizhub C360/C280/C220
MAINTENANCE
7.
To reinstall, reverse the order of removal.
8.
Replace the manual bypass tray separation roller assy.
See P.43
9.
Select [Service Mode]
→
[Counter]
→
[Life] and clear the count of [Manual Tray].
See P.443
4.9.6
Replacing the manual bypass tray separation roller assy
A.
Periodically replacing parts/cycle
•
Manual bypass tray separation roller assy: Every 200,000 counts
B.
Procedure
1.
Remove the rear right cover.
See P.54
2.
Disconnect two connectors [1].
3.
Remove three screws [1], and
remove right door hinge cover [2].
4.
Open the right door.
A0EDF2C007DA
[1]
A0EDF2C008DA
[1]
[2]