Konica Minolta bizhub C280 Service Manual - Page 69
Periodical maintenance 5 life counter; every 550,000 counts
View all Konica Minolta bizhub C280 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
bizhub C360/C280/C220 MAINTENANCE 3. PERIODICAL MIANTENANCE ITEMS Field Service Ver. 1.0 Jul. 2009 D. Periodical maintenance 4 (life counter; every 300,000 counts) No. Section Description/part name 1 Paper feed 2 section Tray 1 pick-up roller Tray 1 feed roller 3 Tray 1 separation roller assy 4 Tray 2 pick-up roller 5 Tray 2 feed roller 6 Tray 2 separation roller assy 7 Processing section Ozone filter 8 Image transfer Transfer belt unit 9 section Transfer roller unit Qt. Clean Check Lubrication Replace Descriptions 1 ● 1 ● 1 ● 1 ● 1 ● 1 ● 1 ● *1 1 ● 1 ● *1 *1: Replace it when replacing transfer belt unit. E. Periodical maintenance 5 (life counter; every 550,000 counts) No. Section Description/part name 1 Fusing section Fusing unit Qt. Clean Check Lubrication Replace Descriptions 1 ● F. Periodical maintenance 6 (life counter; every 600,000 counts) No. Section 1 Processing section Description/part name Developing unit/K Qt. Clean Check Lubrication Replace Descriptions 1 ● 3.1.2 DF-617 A. Periodical maintenance 1 (life counter; every 50,000 counts) No. Section 1 Overall 2 3 Paper feed 4 section 5 6 Conveyance section 7 Scanning section 8 Paper feed section Description/part name Paper feed and image conditions Appearance Pick-up roller Feed roller Separation roller Roller and rolls Scanning guide Reflective sensor section Qt. Clean Check Lubrication Replace Descriptions ⎯ ● ⎯● ● ⎯● ⎯● ⎯● ⎯● ⎯● ⎯● 14