Particular adjustment

Page 82 highlights

5.2 Image Quality Adjustment Carry out the adjustment continuously in sequence. If you have interrupted the adjustment, select "2. Gamma Automatic Adj." to execute automatic gamma adjustment each time before restarting calibration. For example, if you have interrupted the adjustment at the end of the "3. Density Balance Adjustment" processing, select "2. Gamma Automatic Adj." - "4-a. Color Density Control (with Relay Unit RU-509 mounted)" or "4-b. Calibration by image controller (without Relay Unit RU-509 mounted)" to restart the adjustment. If sufficient adjustment results are not obtained via daily maintenance, also carry out the adjustment in this order. For details about the setting procedure, refer to the HTML User's Guide. NOTICE If the setting value is changed in the [Custom Screen], hue may fluctuate significantly. To manage the hue fluctuation, specify the standard image quality following the procedure if you changed the setting value. Particular adjustment If a particular adjustment is required, for example, before printing out an image with a higher level of quality or when the expected chromogenic effect has not been obtained as expected, adjust the following items: Adjustment order 1 2 3 4 Menu item Description Tips Gamma Automatic Adj. Maximum Density Adjustment Color Density Control (with Relay Unit RU-509 mounted) Printer controller calibration Adjusts the curve of the output density against the input density. This affects the brightness and contrast. On the [MACHINE] screen, select [ADJUSTMENT] [Execute Adjust Operation] - [Gamma Automatic Adj.] to execute processing. Changes the maximum density adjustment value when the measurement density that was obtained after calibration does not match the reference adjustment value. [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Process Adjustment] - [Maximum Density Adjustment] Executes automatic calibration when the Relay Unit RU-509 is mounted on this machine. On the [MACHINE] screen, select [ADJUSTMENT] [Color Density Control] - [Basic Setting] or [Color Density Manual Control] to carry out the adjustment. Executes manual calibration when the Relay Unit RU-509 is not mounted on this machine. Use Fiery Command WorkStation. HTML User's Guide HTML User's Guide p. 5-15 p. 5-20 Reference For details about the adjustment procedure, refer to the HTML User's Guide. NOTICE Precautions on mounting the Relay Unit RU-509 To use [Each Paper Type Color Adj.] in [Color Density Control] with the Relay Unit RU-509 mounted, carry out [Each Paper Type Color Adj.] before starting this procedure, then configure a tray setting. For details, refer to the HTML User's Guide. 5-24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143

5-24
5.2
Image Quality Adjustment
Carry out the adjustment continuously in sequence. If you have interrupted the adjustment, select "2. Gamma Auto-
matic Adj." to execute automatic gamma adjustment each time before restarting calibration. For example, if you have
interrupted the adjustment at the end of the "3. Density Balance Adjustment" processing, select "2. Gamma Automatic
Adj." - "4-a. Color Density Control (with
Relay Unit RU-509
mounted)" or "4-b. Calibration by image controller (without
Relay Unit RU-509
mounted)" to restart the adjustment.
If sufficient adjustment results are not obtained via daily maintenance, also carry out the adjustment in this order.
For details about the setting procedure, refer to the
HTML User's Guide
.
NOTICE
If the setting value is changed in the [Custom Screen], hue may fluctuate significantly. To manage the hue fluctuation,
specify the standard image quality following the procedure if you changed the setting value.
Particular adjustment
If a particular adjustment is required, for example, before printing out an image with a higher level of quality or when
the expected chromogenic effect has not been obtained as expected, adjust the following items:
Reference
For details about the adjustment procedure, refer to the
HTML User's Guide
.
NOTICE
Precautions on mounting the
Relay Unit RU-509
To use [Each Paper Type Color Adj.] in [Color Density Control] with the
Relay Unit RU-509
mounted, carry out [Each
Paper Type Color Adj.] before starting this procedure, then configure a tray setting.
For details, refer to the
HTML User's Guide
.
Adjustment
order
Menu item
Description
Tips
1
Gamma Automat-
ic Adj.
Adjusts the curve of the output density against the in-
put density.
This affects the brightness and contrast.
On the [MACHINE] screen, select [ADJUSTMENT] -
[Execute Adjust Operation] - [Gamma Automatic Adj.]
to execute processing.
HTML User's
Guide
2
Maximum Density
Adjustment
Changes the maximum density adjustment value
when the measurement density that was obtained af-
ter calibration does not match the reference adjust-
ment value.
[Administrator Setting] - [System Setting] - [Expert
Adjustment] - [Process Adjustment] - [Maximum Den-
sity Adjustment]
HTML User's
Guide
3
Color Density
Control (with
Re-
lay Unit RU-509
mounted)
Executes automatic calibration when the
Relay Unit
RU-509
is mounted on this machine.
On the [MACHINE] screen, select [ADJUSTMENT] -
[Color Density Control] - [Basic Setting] or [Color Den-
sity Manual Control] to carry out the adjustment.
p. 5-15
4
Printer controller
calibration
Executes manual calibration when the
Relay Unit
RU-509
is not mounted on this machine.
Use
Fiery Command WorkStation
.
p. 5-20