Powerline MU User Guide March, 2007 Powerline MU Inductive Coupler • Useful in individually-metered and multiple transformer buildings such as apartments and condominiums which have one or more meter banks with meters that monitor power consumption to individual residences • Connect one coupler per phase just before the meter bank in the Termination Cabinet over the insulated portion of the electric cable • Provides efficiency in signal distribution by injecting on the larger wires just before the meter bank and subsequent branching to individual residences with no contact to the actual metal conductor • Three coupler sizes to accommodate various wiring gauges 500 Part Number Part Name Description High Voltage Interface Cable Connectors Center Conductor Dimensions Inner Diameter of core Outer Diameter of Core Weight Operating temperature Safety 0171486N21 Powerline MU Inductive Coupler 500 Optional Powerline MU coupler to Induce Signal onto inbuilding cables before the Meter Bank. Fits up to 500 MCM cable rated 380A 75 Ohm Coaxial F-Connector (Coaxial) 600v rated 22-gauge stranded copper THHN wire 2.8 in x 2.3 in x 2.2 in (70.14 mm x 58.3 mm x 55mm) 1 in (25.4 mm) 2.02 in (51.31 mm) .90 lbs -40°C to 55°C (-40°F to 131°F) UL authorization (In conjunction with Powerline MU Gateway) 250 Part Number Part Name Description High Voltage Interface Cable Connectors Center Conductor Dimensions Inner Diameter of core Outer Diameter of Core Weight Operating temperature Safety 0171486N23 Powerline MU Inductive Coupler 250 Optional Powerline MU coupler to Induce Signal onto inbuilding cables before the Meter Bank. Fits up to 250 MCM cable rated 255A 75 Ohm Coaxial F-Connector (Coaxial) 600v rated 22-guage stranded copper THHN wire 2.8 in x 2.3 in x 2.2 in (70.14 mm x 58.3 mm x 55mm) .76 in (19.4 mm) 2.02 in (51.31 mm) .99 lbs -40°C to 55°C (-40°F to 131°F) UL authorization (In conjunction with Powerline MU Gateway) Issue 2.0 Page 99 of 112

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Powerline MU User Guide
March, 2007
Issue 2.0
Page 99 of 112
Powerline MU Inductive Coupler
Useful in individually-metered and multiple
transformer buildings such as apartments and
condominiums which have one or more meter
banks with meters that monitor power
consumption to individual residences
Connect one coupler per phase just before the
meter bank in the Termination Cabinet over the
insulated portion of the electric cable
Provides efficiency in signal distribution by
injecting on the larger wires just before the meter bank and subsequent branching to
individual residences with no contact to the actual metal conductor
Three coupler sizes to accommodate various wiring gauges
500
Part Number
0171486N21
Part Name
Powerline MU Inductive Coupler 500
Description
Optional Powerline MU coupler to Induce Signal onto in-
building cables before the Meter Bank.
High Voltage Interface
Fits up to 500 MCM cable rated 380A
Cable
75 Ohm Coaxial
Connectors
F-Connector (Coaxial)
Center Conductor
600v rated 22-gauge stranded copper THHN wire
Dimensions
2.8 in x 2.3 in x 2.2 in (70.14 mm x 58.3 mm x 55mm)
Inner Diameter of core
1 in (25.4 mm)
Outer Diameter of Core
2.02 in (51.31 mm)
Weight
.90 lbs
Operating temperature
-40°C to 55°C (-40°F to 131°F)
Safety
UL authorization
(In conjunction with Powerline MU Gateway)
250
Part Number
0171486N23
Part Name
Powerline MU Inductive Coupler 250
Description
Optional Powerline MU coupler to Induce Signal onto in-
building cables before the Meter Bank.
High Voltage Interface
Fits up to 250 MCM cable rated 255A
Cable
75 Ohm Coaxial
Connectors
F-Connector (Coaxial)
Center Conductor
600v rated 22-guage stranded copper THHN wire
Dimensions
2.8 in x 2.3 in x 2.2 in (70.14 mm x 58.3 mm x 55mm)
Inner Diameter of core
.76 in (19.4 mm)
Outer Diameter of Core
2.02 in (51.31 mm)
Weight
.99 lbs
Operating temperature
-40°C to 55°C (-40°F to 131°F)
Safety
UL authorization (In conjunction with Powerline MU Gateway)