Panasonic AJ-HDX900 Dvcpro Hd Camera - Page 106

continued, 2-9 OPTION MODE

Page 106 highlights

Chapter 7 Menu description tables (continued) 7-2-9 OPTION MODE Item REC TALLY CUF P.OFF GPS DATA CUF 1394 SPEED CUF 1394 IN CH CUF 1394 OUT CH CUF 1394 CONTROL CUF 1394 CMD SEL CUF SDI METADATA CUF SDI EDH CUF Variable range RED GREEN CHAR HOLD CLEAR S200 S400 0 : 63 AUTO 0 : 63 AUTO OFF BOTH REC_P STOP ON OFF ON OFF Remarks For selecting the method to access records on the unit when the unit is connected to peripheral devices and used remotely. RED: The red tally lamp lights. GREEN: The green tally lamp lights. CHAR: For displaying "REC" in the viewfinder. For selecting whether or not to hold the UMID GPS position information while the power is off and record the information as the data still held as the previous value until another measurement can be taken after the power is next turned on. HOLD: The data is held and recorded. CLEAR: The data is cleared at the same time as the power is turned off, and all zeros (no information) are recorded from the time the power is turned on until the measurement is next taken. For setting the transfer rate of signals output from the DVCPRO connector. S200: 200 Mbps S400: 400 Mbps For setting the input channel of signals input to the DVCPRO connector. 0 - 63: To fix to the designated value AUTO: To follow the settings of the externally connected devices For setting the input channel of signals output from the DVCPRO connector. 0 - 63: To fix to the designated value AUTO: To follow the settings of the externally connected devices For setting the control for recording start/stop operations of external devices that are connected to the DVCPRO connector. OFF: Do not control the externally connected devices. BOTH: To control both the unit and the externally connected devices For setting the control of recording stop operations of the external devices that are connected to the DVCPRO connector. REC_P: Operation to pause recording STOP: Stopping operation For setting metadata (UMID information) to output to the HD SDI signals. ON: To output OFF: Not to output For setting that the detection signals of the communication error is output to the HD SDI signals. ON: To output OFF: Not to output The underlining in the variable range column indicates the setting in the preset mode. 106

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

106
Chapter 7
Menu description tables
(continued)
The underlining in the variable range column indicates the setting in the preset
mode.
7-2-9 OPTION MODE
Item
Variable
range
Remarks
P.OFF GPS DATA
HOLD
CLEAR
For selecting whether or not to hold the
UMID GPS position information while the
power is off and record the information as
the data still held as the previous value until
another measurement can be taken after the
power is next turned on.
HOLD:
The data is held and recorded.
CLEAR:
The data is cleared at the same
time as the power is turned off, and
all zeros (no information) are
recorded from the time the power is
turned on until the measurement is
next taken.
REC TALLY
RED
GREEN
CHAR
For selecting the method to access records
on the unit when the unit is connected to
peripheral devices and used remotely.
RED:
The red tally lamp lights.
GREEN:
The green tally lamp lights.
CHAR:
For displaying
REC
in the
viewfinder.
CU
F
CU
F
1394 SPEED
S200
S400
For setting the transfer rate of signals output
from the DVCPRO connector.
S200:
200 Mbps
S400:
400 Mbps
CU
F
1394 IN CH
0
:
63
AUTO
For setting the input channel of signals input
to the DVCPRO connector.
0
63:
To fix to the designated value
AUTO:
To follow the settings of the
externally connected devices
CU
F
1394 OUT CH
0
:
63
AUTO
For setting the input channel of signals
output from the DVCPRO connector.
0
63:
To fix to the designated value
AUTO:
To follow the settings of the
externally connected devices
CU
F
1394 CONTROL
OFF
BOTH
For setting the control for recording
start/stop operations of external devices that
are connected to the DVCPRO connector.
OFF:
Do
not
control
the
externally
connected devices.
BOTH:
To control both the unit and the
externally connected devices
CU
F
1394 CMD SEL
REC_P
STOP
For setting the control of recording stop
operations of the external devices that are
connected to the DVCPRO connector.
REC_P:
Operation to pause recording
STOP:
Stopping operation
CU
F
SDI METADATA
ON
OFF
For setting metadata (UMID information) to
output to the HD SDI signals.
ON:
To output
OFF:
Not to output
CU
F
SDI EDH
ON
OFF
For setting that the detection signals of the
communication error is output to the HD SDI
signals.
ON:
To output
OFF:
Not to output
CU
F