Panasonic AJ-HDX900 Dvcpro Hd Camera - Page 98

Warning system

Page 98 highlights

Chapter 6 Maintenance and inspections (continued) 6-3 Warning system 6-3-1 Warning description tables When an error or a problem is detected immediately after the power is turned on or while an operation is underway, the WARNING lamp and lamps inside the viewfinder serve to alert the user. Items are displayed in the following sequence of priority: WARNING lamp > tally lamp > warnings inside the viewfinder. The display accords with this sequence when more than one error has occurred at the same time. However, WIRELESS RF may not be displayed depending on the menu setting selected. 1. SLACK Indications on LCD screen WARNING lamp Tally lamp Viewfinder Alarm Warning description VTR unit operation Corrective action "SLACK" appears and an error code flashes. Flashes four times a second. Flashes four times a second. "SLACK" appears and an error code lights up. Sounds continuously. Motor, solenoid or other mechanism-related trouble, etc. Operation is stopped. Power is turned off if solenoid trouble has been detected. Check "6-3-2 Error codes," and consult your dealer. 2. BATTERY END Indications on LCD screen WARNING lamp Tally lamp Viewfinder Alarm Warning description VTR unit operation Corrective action The bar display that shows the remaining battery charge starts flashing. Lights. Flashes once a second. BATT LED lights. Sounds continuously. The battery charge is now depleted. All operations are stopped, and the tape is unloaded. Only cassette tape eject is accepted. Replace the battery. 3. TAPE END Indications on LCD screen WARNING lamp Tally lamp Viewfinder Alarm Warning description VTR unit operation Corrective action The bar display that shows the remaining tape amount starts flashing. Lights (during stop and standby OFF). Flashes four times a second (during stop and standby OFF). "= END" flashes (during stop and standby OFF). Sounds continuously (during stop and standby OFF). The tape has come to its end. Operation is stopped during recording, playback and fast forwarding. Rewind the tape or replace the cassette tape. 4. REC WARNING Indications on LCD screen WARNING lamp Tally lamp Viewfinder Alarm Warning description VTR unit operation Corrective action The code 11 display lights. Flashes four times a second (for at least 3 seconds during recording). Flashes four times a second (for at least 3 seconds during recording). REC WARNING display flashes (for at least 3 seconds during recording). Sounds four times a second (for at least 3 seconds during recording). Problem with the recording control signal. Recording continues but the signals may not be recorded correctly while the warning remains displayed. Rewind the tape or replace the cassette tape. 5. HUMID Indications on LCD screen WARNING lamp Tally lamp Viewfinder Alarm Warning description VTR unit operation Corrective action "HUMID" display lights if condensation is detected. "HUMID" display flashes for an additional 10 to 90 minutes after condensation detection is canceled. Lights for 90 minutes following the release of the condensation detection after the condensation formation was detected. Flashes 4 times per second for 90 minutes after condensation detection is canceled. "HUMID" display flashes from the time condensation is detected until 90 minutes after the condensation detection is released. Sounds continuously (4 times a second during recording). Condensation has formed. The recording operation continues but if the tape sticks, recording will stop. For 80 minutes after the condensation detection is released, the drum is rotated and no operations are accepted. Stop the tape travel and turn off the power. If the "HUMID" display fails to be cleared even when the power is turned back on, wait until it clears. 98

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

98
5. HUMID
WARNING lamp
Lights for 90 minutes following the release of the
condensation detection after the condensation
formation was detected.
Indications on LCD
screen
HUMID
display lights if condensation is
detected.
HUMID
display flashes for an additional 10 to
90 minutes after condensation detection is
canceled.
Tally lamp
Flashes 4 times per second for 90 minutes after
condensation detection is canceled.
Viewfinder
HUMID
display
flashes
from
the
time
condensation is detected until 90 minutes after
the condensation detection is released.
Alarm
Sounds continuously (4 times a second during
recording).
Warning description
Condensation has formed.
VTR unit operation
The recording operation continues but if the tape
sticks, recording will stop.
For 80 minutes after the condensation detection
is released, the drum is rotated and no
operations are accepted.
Corrective action
Stop the tape travel and turn off the power.
If the
HUMID
display fails to be cleared even when
the power is turned back on, wait until it clears.
6-3 Warning system
6-3-1 Warning description tables
When an error or a problem is detected immediately after the power is turned on or while an operation is underway, the
WARNING lamp and lamps inside the viewfinder serve to alert the user.
<Note>
Items are displayed in the following sequence of priority: WARNING lamp > tally lamp > warnings inside the viewfinder.
The
display accords with this sequence when more than one error has occurred at the same time.
However, WIRELESS RF may
not be displayed depending on the menu setting selected.
1. SLACK
WARNING lamp
Flashes four times a second.
Indications on LCD
screen
SLACK
appears and an error code flashes.
Tally lamp
Flashes four times a second.
Viewfinder
SLACK
appears and an error code lights up.
Alarm
Sounds continuously.
Warning description
Motor, solenoid or other mechanism-related
trouble, etc.
VTR unit operation
Operation is stopped.
Power is turned off if
solenoid trouble has been detected.
Corrective action
Check
6-3-2 Error codes,
and consult your
dealer.
WARNING lamp
Flashes four times a second (for at least 3
seconds during recording).
Indications on LCD
screen
The code 11 display lights.
Tally lamp
Flashes four times a second (for at least 3
seconds during recording).
Viewfinder
REC WARNING display flashes (for at least 3
seconds during recording).
Alarm
Sounds four times a second (for at least 3
seconds during recording).
Warning description
Problem with the recording control signal.
VTR unit operation
Recording continues but the signals may not be
recorded correctly while the warning remains
displayed.
Corrective action
Rewind the tape or replace the cassette tape.
WARNING lamp
Lights (during stop and standby OFF).
Indications on LCD
screen
The bar display that shows the remaining tape
amount starts flashing.
Tally lamp
Flashes four times a second (during stop and
standby OFF).
Viewfinder
=
END
flashes (during stop and standby
OFF).
Alarm
Sounds continuously (during stop and standby
OFF).
Warning description
The tape has come to its end.
VTR unit operation
Operation is stopped during recording, playback
and fast forwarding.
Corrective action
Rewind the tape or replace the cassette tape.
WARNING lamp
Lights.
Indications on LCD
screen
The bar display that shows the remaining battery
charge starts flashing.
Tally lamp
Flashes once a second.
Viewfinder
BATT LED lights.
Alarm
Sounds continuously.
Warning description
The battery charge is now depleted.
VTR unit operation
All operations are stopped, and the tape is
unloaded.
Only cassette tape eject is accepted.
Corrective action
Replace the battery.
4. REC WARNING
2. BATTERY END
3. TAPE END
Chapter 6
Maintenance and inspections
(continued)