Sharp PG-LS2000 PG-LX2000 PG-LS2000 Operation Manual - Page 60

Resetting the Lamp Timer

Page 60 highlights

Regarding the Lamp (Continued) 4 Remove the lamp unit. • Loosen the securing screw from the lamp unit. Hold the lamp unit and pull it in the direction of the arrow. At this time, keep the lamp unit horizontal and do not tilt it. Securing screw 5 Insert the new lamp unit. • Press the lamp unit firmly into the lamp unit compartment to align the lamp connectors. Fasten the securing screw. 6 Replace the lamp unit cover. • Slide the lamp unit cover horizontally back into place and align the tabs (1). Then tighten the user service screw (2) to secure the lamp unit cover. Info • If the lamp unit and lamp unit cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector. Resetting the Lamp Timer Reset the lamp timer after replacing the lamp. Info • Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or explode. 1 Connect the power cord. • Plug the power cord into the AC socket of the projector. 2 Reset the lamp timer. • While simultaneously holding down MENU, ENTER and R on the projector, press STANDBY/ON on the projector and keep all four buttons pressed down until the lamp indicator starts blinking green. • "LAMP 0000H" is displayed, indicating that the lamp timer is reset. 58 AC socket STANDBY/ON button ENTER button MENU button R button

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

58
4
Remove the lamp unit.
Loosen the securing screw from the lamp
unit. Hold the lamp unit and pull it in the
direction of the arrow. At this time, keep
the lamp unit horizontal and do not tilt it.
5
Insert the new lamp unit.
Press the lamp unit firmly into the lamp unit
compartment to align the lamp connectors.
Fasten the securing screw.
6
Replace the lamp unit cover.
Slide the lamp unit cover horizontally back
into place and align the tabs (
1
). Then
tighten the user service screw (
2
) to
secure the lamp unit cover.
Info
If the lamp unit and lamp unit cover
are not correctly installed, the power
will not turn on, even if the power
cord is connected to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Info
Make sure to reset the lamp timer only when
replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or
explode.
1
Connect the power cord.
Plug the power cord into the AC socket of
the projector.
2
Reset the lamp timer.
While simultaneously holding down
MENU
,
ENTER
and
R
on the projector,
press
STANDBY/ON
on the projector and
keep all four buttons pressed down until
the lamp indicator starts blinking green.
“LAMP 0000H” is displayed, indicating
that the lamp timer is reset.
4
5
6
AC socket
AC socket
1
ENTER button
MENU button
R
button
STANDBY/ON
button
ENTER button
MENU button
R
button
STANDBY/ON
button
2
Regarding the Lamp (Continued)
Securing
screw