Sony HTIS100 Operating Instructions - Page 27
Confirming/saving the, measurement result, When error codes appear, When you select WRN CHECK - surround sound system
UPC - 027242731332
View all Sony HTIS100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Getting Started Confirming/saving the measurement result 1 Confirm the measurement result. When the measurement ends, a beep sounds and the measurement result appears on the top panel display. Item SAVE EXIT WRN CHECK DIST INFO LEVEL INFO EXIT Explanation Saves the measurement result and exits the setting process. Displays warning concerning the measurement result. See "When you select "WRN CHECK"" (page 27). Displays the measurement result for speaker distance. Displays the measurement result for speaker level. Exits the setting process without saving the measurement result. Note • After "SAVE EXIT" is displayed for 50 seconds, the measurement result is saved automatically, without the need to saving procedure. 2 Press x/X repeatedly to select the desired item, then press or c. To return, press C or RETURN. 3 Save the measurement result. Select "SAVE EXIT" in step 2, then press . The measurement result is saved. When error codes appear Try the remedies and perform the Auto Calibration again. Item ERROR 32 Explanation • The sound input from the calibration mic is out of the acceptable range. • The calibration mic or subwoofer may be damaged. Contact your Sony dealer or local authorized Sony service facility. Item ERROR F 33 ERROR SR 33 ERROR SW 33 Explanation The front speakers are not connected. Check that the front speakers are connected properly. Either the surround left or surround right speaker is not connected. Check that the surround speakers are connected properly. The subwoofer may be damaged. Contact your Sony dealer or local authorized Sony service facility. When you select "WRN CHECK" If a warning on the measurement result is present, detailed information is displayed. Warning code WARNING 40 WARNING 41 WARNING 42 WARNING 43 NO WARNING Explanation The Auto Calibration has completed. However, the noise level is high. You may be able to perform the Auto Calibration properly if you try it again, even though the measurement cannot be performed in all environments. Try to perform the Auto Calibration in a quiet environment. The sound input from the calibration mic is out of the acceptable range. The distance between the calibration mic and the speakers is too closed. Set them away, and then try to perform the Auto Calibration. The distance and position of the subwoofer cannot be detected. This may be caused by noise. Try to perform the Auto Calibration in a quiet environment. There is no warning information. continued 27US