2. PREPARATION 2-8.Using the air unit r w t q e y 1. Attach the air hose q to the air unit connector w with the nut e. 2. Use air pressure at 0.49 MPa - 0.54 MPa (5 - 5.5 kgf/cm2). Pull up the cap at the top of the air unit r and adjust the pressure. After adjustment, push the cap down to lock it. NOTE: Every day, close the air cock t and push the drain cock y to remove the water. 2-9.Pulley rotation direction Turn on the power switch. Confirm that the pulley rotates in the direction of the arrow. ʕ 8 ʕ B A S -705
2. PREPARATION
2-8.Using the air unit
2-9.Pulley rotation direction
Turn on the power switch.
Confirm that the pulley ro-
tates in the direction of the arrow.
―
8
―
BAS-705
q
t
w
r
e
�
y
1.
Attach the air hose
q
to the air unit connector
w
with the nut
e
.
2.
Use air pressure at 0.49 MPa - 0.54 MPa (5 - 5.5
kgf/cm
2
).
Pull up the cap at the top of the air unit
r
and adjust
the pressure.
After adjustment, push the cap down
to lock it.
NOTE:
Every day, close the air cock
t
and push the
drain cock
y
to remove the water.