Cisco 7206VXR Installation Guide - Page 52
temperature sensor and for each monitored status level
UPC - 746320975061
View all Cisco 7206VXR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Functional Overview Chapter 1 Product Overview The show environment last command retrieves and displays the NVRAM log, which shows the reason for the last system shutdown (if the shutdown was related to voltage or temperature) and the environmental status at that time. Air temperature is measured and displayed, and the DC voltage supplied by the power supply is also displayed. Following is sample output of the show environment last command: Router# show environment last Temperature readings: chassis inlet previously measured at 27C/80F chassis outlet 1 previously measured at 31C/87F chassis outlet 2 previously measured at 37C/98F chassis outlet 3 previously measured at 45C/113F Voltage readings: +3.45 V previously measured at +3.51 V +5.2 V previously measured at +5.19 V +12.2 V previously measured at +12.42 V -12.2 V previously measured at -12.14 V Reason for last shutdown: power supply The show environment table command displays the temperature and voltage thresholds for each temperature sensor and for each monitored status level, which are related to those thresholds listed in Table 1-10 and Table 1-11. The display also lists the shutdown threshold for the system. Following is sample output of the show environment table command for a Cisco 7206 that has an installed NPE-150: Router# show environment table Sample Point LowCritical LowWarning chassis inlet chassis outlet 1 chassis outlet 2 chassis outlet 3 +3.45 V +3.26 +3.34 +5.15 V +4.86 +4.99 +12.15 V +11.39 +11.67 -11.95 V -9.52 -10.73 System shutdown for chassis outlet 1 58C/136F System shutdown for chassis outlet 3 70C/158F HighWarning HighCritical 40C/104F 50C/122F 43C/109F 53C/127F 75C/167F 75C/167F 55C/131F 65C/149F +3.55 +3.63 +5.31 +5.43 +12.62 +12.91 -13.16 -14.38 Following is sample output of the show environment table command for a Cisco 7206 that has an installed NPE-100 or NPE-200: Router# show environment table Sample Point LowCritical LowWarning chassis inlet chassis outlet 1 chassis outlet 2 chassis outlet 3 +3.45 V +3.26 +3.34 +5.15 V +4.86 +4.99 +12.15 V +11.39 +11.67 -11.95 V -9.52 -10.73 System shutdown for chassis outlet 1 58C/136F System shutdown for chassis outlet 3 65C/149F HighWarning 40C/104F 43C/109F 75C/167F 50C/122F +3.55 +5.31 +12.62 -13.16 HighCritical 50C/122F 53C/127F 75C/167F 60C/140F +3.63 +5.43 +12.91 -14.38 1-34 Cisco 7206 Installation and Configuration Guide OL-5102-02