Compaq ProLiant 800 ProLiant 800 Servers Supporting Pentium II Processors and - Page 85

Event Messages, Integrated Management Log - cpu fan

Page 85 highlights

5-6 Integrated Management Log Event Messages continued Event Type POST Error Power Subsystem Power Supply Failure Power Supply Inserted Power Supply Removed Power Supply Not Redundant System Configuration Battery Low Power Module Failure Power Modules Not Redundant AC Voltage Problem Power AC Overload Automatic Server Recovery System Lockup Operating System System Crash Automatic OS Shutdown Event Message POST Error: Error message System Power Supply Failure (Power Supply X) System Power Supply Inserted (Power Supply X) System Power Supply Removed (Power Supply X) System Power Supplies Not Redundant Real-Time Clock Battery Failing A CPU Power Module (System Board, Socket X) A CPU Power Module (Slot X, Socket X) System Power Modules Not Redundant System AC Power Problem (Power Supply X) System AC Power Overload (Power Supply X) ASR Lockup Detected: Cause Blue Screen Trap: Cause [NT] Kernel Panic: Cause [UNIX] Abnormal Program Termination: Cause [NetWare] Automatic Operating System Shutdown Initiated Due to Fan Failure Automatic Operating System Shutdown Initiated Due to Overheat Condition Fatal Exception (Number X, Cause)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

5-6
Integrated Management Log
Event Messages
continued
Event Type
Event Message
POST Error
POST Error: Error message
Power Subsystem
Power Supply Failure
Power Supply Inserted
Power Supply Removed
Power Supply Not
Redundant
System Configuration
Battery Low
Power Module Failure
Power Modules Not
Redundant
AC Voltage Problem
Power AC Overload
System Power Supply Failure (Power Supply X)
System Power Supply Inserted (Power Supply X)
System Power Supply Removed (Power Supply X)
System Power Supplies Not Redundant
Real-Time Clock Battery Failing
A CPU Power Module (System Board, Socket X)
A CPU Power Module (Slot X, Socket X)
System Power Modules Not Redundant
System AC Power Problem (Power Supply X)
System AC Power Overload (Power Supply X)
Automatic Server Recovery
System Lockup
ASR Lockup Detected: Cause
Operating System
System Crash
Automatic OS
Shutdown
Blue Screen Trap: Cause [NT]
Kernel Panic: Cause [UNIX]
Abnormal Program Termination: Cause [NetWare]
Automatic Operating System Shutdown Initiated Due to
Fan Failure
Automatic Operating System Shutdown Initiated Due to
Overheat Condition
Fatal Exception (Number X, Cause)