EMC CX500I Configuration Guide - Page 118

Storage-System Installation Types

Page 118 highlights

Storage-System Hardware Storage-System Installation Types The storage systems attach to the server and the interconnect components as described in Chapter 1. The installation types are ◆ Unshared direct, with one server, is the simplest and least costly; ◆ Shared-or-clustered direct, with a limit of two servers, lets two servers share storage resources with high availability; and ◆ Shared switched, which has two switch fabrics, lets two or more servers share the resources of several storage systems in a storage area network (SAN). Table 6-1 illustrates the storage-system installation types. CX300, CX500, CX500i, and CX700 storage systems require at least one network connection for management. Unshared Direct Shared or Clustered (One or Two Servers) Direct (Two Servers) Server Server Server Shared Switched (Multiple Servers, Multiple Paths to SPs) Server Server Server Adapter Adapter Adapter Adapter Adapter Adapter Adapter Adapter Adapter Adapter Adapter Adapter Server Component Interconnect Component FC Switch or LAN FC Switch or LAN Storage SP A SP B Component Storage System SP A SP B Storage System SP A SP B SP A SP B SP A SP B Storage System Storage System Storage System Path 1 Path 2 EMC1826a Figure 6-1 Types of Fibre Channel Storage-System Installations 6-2 EMC CLARiiON CX300, CX500, CX500i, and CX700 Storage Systems Configuration Planning Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

6-2
EMC CLARiiON CX300, CX500, CX500i, and CX700 Storage Systems Configuration Planning Guide
Storage-System Hardware
Storage-System Installation Types
The storage systems attach to the server and the interconnect
components as described in Chapter 1. The installation types are
Unshared direct
, with one server, is the simplest and least costly;
Shared-or-clustered direct
, with a limit of two servers, lets two
servers share storage resources with high availability; and
Shared switched
, which has two switch fabrics, lets two or more
servers share the resources of several storage systems in a storage
area network (SAN).
Table 6-1 illustrates the storage-system installation types.
CX300, CX500, CX500i, and CX700 storage systems require at least one
network connection for management.
Figure 6-1
Types of Fibre Channel Storage-System Installations
EMC1826a
Server
Component
Interconnect
Component
Storage
Component
Unshared Direct
(One or Two Servers)
Shared or Clustered
Direct (Two Servers)
Shared Switched (Multiple Servers,
Multiple Paths to SPs)
Adapter
Server
Server
Server
Server
Server
Server
Path 1
Path 2
SP A
SP B
SP A
SP B
SP A
SP B
SP A
SP B
SP A
SP B
Storage System
Storage System
Storage System
Storage System
Storage System
Adapter
Adapter
Adapter
Adapter
Adapter
Adapter
Adapter
Adapter
Adapter
Adapter
Adapter
FC Switch
or
LAN
FC Switch
or
LAN