EMC CX500I Configuration Guide - Page 99
Sample Unshared Direct Installation, LUNs - SP A and SP B - 1, 440 Gbytes on Seven LUNs, Disk IDs
View all EMC CX500I manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
Planning File Systems and LUNs Sample Unshared Direct Installation This section shows the disks and LUNs in an unshared direct storage-system installation. Server SP A SP B R5 R5 Specs Specs 100-1014 R5 R5 R5 000-0014 Dbase1 Dbase2 Mail Figure 5-2 Unshared Direct Storage System EMC2404 The example below describes a storage system with two back-end loops. Each disk holds 73 Gbytes, so the storage system provides the server with 504 Gbytes of disk storage, all highly available. The storage-system disk IDs and LUNs are as follows: LUNs - SP A and SP B - 1,440 Gbytes on Seven LUNs Disk IDs RAID Type Storage Type, Capacity, Drive 000-004 005-009 RAID 5 RAID 5 Dbase1, 292 Mbytes, drive G Dbase2, 292 Mbytes, drive H 0010-0014 RAID 5 Mail, 292 Mbytes, drive I 101-102 RAID 1 Log file, Dbase1, 73 Mbytes, drive J 103-104 RAID 1 Log file, Dbase2, 73 Mbytes, drive K 105-109 RAID 1 Users, 292 Mbytes, drive L 1010-1014 RAID 5 Specs, 292 Mbytes, drive M 100 - Hot spare (automatically replaces a failed disk in any LUN) Note: The available storage is 50% for a RAID 1 LUN and 80% for a 5-disk RAID 5 LUN. Sample Unshared Direct Installation 5-5