B.1.2, Set Standby Frequency, Remote Ident Input, Message Format, Example Message

Page 64 highlights

B.1.2 Set Standby Frequency Message Format $PMRRC01mka 01 .......message id mk ......standby frequency: m = desired frequency in MHz in hexadecimal, where m = desired frequency 30h , with desired frequency in range of 118 to 136 MHz, or 162 MHz. k = desired frequency in kHz where k = (desired frequency / 25 kHz) + 30h, with desired frequency in range of 000 to 975 kHz in 25 kHz steps, or 0 to 39. a..........transceiver function: N = normal receive operation M = enable monitor function 0 = no change Example Message $PMRRC01LFM40 Set the standby frequency to 124.550 MHz, monitor function selected B.1.3 Remote Ident Input This message is used to input a new ident, and reset the remote frequency input pointer. Message Format $PMRRC04tiiii 04 .......message id t ..........list type, input 1 iiii.......ident, four character ascii Example Message $PMRRC041SLE99 Set the remote frequency ident to "SLE." GTR 200 Installation Manual Page B-2 190-01553-00 Rev. A

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

GTR 200 Installation Manual
190-01553-00
Page B-2
Rev. A
B.1.2
Set Standby Frequency
Message Format
$PMRRC01mka<chksum><cr>
01
.......
message id
mk
......
standby frequency:
m = desired frequency in MHz in hexadecimal, where m = desired frequency -
30h , with desired frequency in range of 118 to 136 MHz, or 162 MHz.
k = desired frequency in kHz where k = (desired frequency / 25 kHz) + 30h, with
desired frequency in range of 000 to 975 kHz in 25 kHz steps, or 0 to 39.
a
..........
transceiver function:
N = normal receive operation
M = enable monitor function
0 = no change
Example Message
$PMRRC01LFM40<cr>
Set the standby frequency to 124.550 MHz, monitor function selected
B.1.3
Remote Ident Input
This message is used to input a new ident, and reset the remote frequency input pointer.
Message Format
$PMRRC04tiiii<chksum><cr>
04
.......
message id
t
..........
list type, input 1
iiii
.......
ident, four character ascii
Example Message
$PMRRC041SLE<space>99<cr>
Set the remote frequency ident to “SLE.”