HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 35
Table 8, command summary, 8Gb SAN Switch for HP BladeSystem c-Class
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Table 8 portcfgfillword command summary (continued) Fabric OS version All 8-Gb switches except 8-Gb SAN Fabric 8Gb SAN Switch for HP BladeSystem c-Class OS version Switch for HP BladeSystem c-Class 6.1.2x and 6.2.0c and Added the ability to change later (HP did not support portcfgfillword to mode 0 or mode 1 6.1.2c or 6.2.0c) on a port-by-port basis. Added the ability to change portcfgfillword to mode 0 or mode 1 on a port-by-port basis. NOTE: Fabric OS 6.1.2 was not supported on this switch. 6.1.2x and 6.2.0d through 6.3.0x The default setting for all ports is mode 0, • If version 6.2.0d was installed in the regardless of what Fabric OS version was factory, the default setting is mode 1 for previously installed. However, ports previously the internal ports and mode 0 for the set to mode 1 by the user via the external ports. The setting can be changed portcfgfillword command are persistent, by the user on a port-by-port basis and will and will therefore remain at mode 1 after be persistent. Upgrading to a 6.3.0x Fabric OS upgrade. version does not affect the current mode settings. • If a pre-6.2.0d version was installed in the factory, the default setting for all internal and external ports is mode 0. The setting can be changed by the user on a port-by-port basis and will be persistent. Upgrading to one of the versions in the left column does not affect the current mode settings. 6.3.1a and later Implemented support for modes 2 and 3 as described below. The default setting for all ports is mode 0, regardless of what Fabric OS version was previously installed. However, ports previously set to mode 1 by the user via the portcfgfillword command are persistent, and will therefore remain at mode 1 after Fabric OS upgrade. • If version 6.2.0d or 6.3.1c was installed in the factory, the default setting is mode 1 for the internal ports and mode 0 for the external ports. The setting can be changed by the user on a port-by-port basis and will be persistent. Upgrading to a version later than 6.3.1c does not affect the current mode settings. • If a pre-6.2.0d version was installed in the factory, the default setting for all internal and external ports is mode 0. The setting can be changed by the user on a port-by-port basis and will be persistent. Upgrading to version 6.3.1a or later does not affect the current mode setting, with the exception of version 6.4.0b or later as described below. • If upgraded to version 6.4.0b, regardless of what version was factory installed, all internal ports will be set to mode 1, and all external ports to mode 0. The setting can be changed by the user on a port-by-port basis and will be persistent. Modes 0-Idle for link init, idle for fill word 1-Arb(ff) for link init, arb(ff) for fill word (not supported with EVA or XP storage arrays) 2-Idle for link init, arb(ff) for fill word 3-Initially attempts mode 1 link initialization. If unsuccessful in achieving active state, reverts to mode 2. Steady state fill word is arb(ff) (not supported with XP storage arrays earlier than Fabric OS 6.4.0a.) Important notes and recommendations 35