HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 35

Table 8, command summary, 8Gb SAN Switch for HP BladeSystem c-Class

Page 35 highlights

Table 8 portcfgfillword command summary (continued) Fabric OS version All 8-Gb switches except 8-Gb SAN Fabric 8Gb SAN Switch for HP BladeSystem c-Class OS version Switch for HP BladeSystem c-Class 6.1.2x and 6.2.0c and Added the ability to change later (HP did not support portcfgfillword to mode 0 or mode 1 6.1.2c or 6.2.0c) on a port-by-port basis. Added the ability to change portcfgfillword to mode 0 or mode 1 on a port-by-port basis. NOTE: Fabric OS 6.1.2 was not supported on this switch. 6.1.2x and 6.2.0d through 6.3.0x The default setting for all ports is mode 0, • If version 6.2.0d was installed in the regardless of what Fabric OS version was factory, the default setting is mode 1 for previously installed. However, ports previously the internal ports and mode 0 for the set to mode 1 by the user via the external ports. The setting can be changed portcfgfillword command are persistent, by the user on a port-by-port basis and will and will therefore remain at mode 1 after be persistent. Upgrading to a 6.3.0x Fabric OS upgrade. version does not affect the current mode settings. • If a pre-6.2.0d version was installed in the factory, the default setting for all internal and external ports is mode 0. The setting can be changed by the user on a port-by-port basis and will be persistent. Upgrading to one of the versions in the left column does not affect the current mode settings. 6.3.1a and later Implemented support for modes 2 and 3 as described below. The default setting for all ports is mode 0, regardless of what Fabric OS version was previously installed. However, ports previously set to mode 1 by the user via the portcfgfillword command are persistent, and will therefore remain at mode 1 after Fabric OS upgrade. • If version 6.2.0d or 6.3.1c was installed in the factory, the default setting is mode 1 for the internal ports and mode 0 for the external ports. The setting can be changed by the user on a port-by-port basis and will be persistent. Upgrading to a version later than 6.3.1c does not affect the current mode settings. • If a pre-6.2.0d version was installed in the factory, the default setting for all internal and external ports is mode 0. The setting can be changed by the user on a port-by-port basis and will be persistent. Upgrading to version 6.3.1a or later does not affect the current mode setting, with the exception of version 6.4.0b or later as described below. • If upgraded to version 6.4.0b, regardless of what version was factory installed, all internal ports will be set to mode 1, and all external ports to mode 0. The setting can be changed by the user on a port-by-port basis and will be persistent. Modes 0-Idle for link init, idle for fill word 1-Arb(ff) for link init, arb(ff) for fill word (not supported with EVA or XP storage arrays) 2-Idle for link init, arb(ff) for fill word 3-Initially attempts mode 1 link initialization. If unsuccessful in achieving active state, reverts to mode 2. Steady state fill word is arb(ff) (not supported with XP storage arrays earlier than Fabric OS 6.4.0a.) Important notes and recommendations 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

Table 8
portcfgfillword
command summary
(continued)
8Gb SAN Switch for HP BladeSystem c-Class
All 8-Gb switches except 8-Gb SAN Fabric
OS version Switch for HP BladeSystem c-Class
Fabric OS version
Added the ability to change
portcfgfillword
to mode 0 or mode 1
on a port-by-port basis.
NOTE:
Fabric OS 6.1.2 was not supported
on this switch.
Added the ability to change
portcfgfillword
to mode 0 or mode 1
on a port-by-port basis.
6.1.2x and 6.2.0c and
later (HP did not support
6.1.2c or 6.2.0c)
If version 6.2.0d was installed in the
factory, the default setting is mode 1 for
the internal ports and mode 0 for the
external ports. The setting can be changed
by the user on a port-by-port basis and will
be persistent. Upgrading to a 6.3.0x
version does not affect the current mode
settings.
If a pre-6.2.0d version was installed in the
factory, the default setting for all internal
and external ports is mode 0. The setting
can be changed by the user on a
port-by-port basis and will be persistent.
Upgrading to one of the versions in the
left column does not affect the current
mode settings.
The default setting for all ports is mode 0,
regardless of what Fabric OS version was
previously installed. However, ports previously
set to mode 1 by the user via the
portcfgfillword
command are persistent,
and will therefore remain at mode 1 after
Fabric OS upgrade.
6.1.2x and 6.2.0d
through 6.3.0x
If version 6.2.0d or 6.3.1c was installed
in the factory, the default setting is mode
1 for the internal ports and mode 0 for the
external ports. The setting can be changed
by the user on a port-by-port basis and will
be persistent. Upgrading to a version later
than 6.3.1c does not affect the current
mode settings.
If a pre-6.2.0d version was installed in the
factory, the default setting for all internal
and external ports is mode 0. The setting
can be changed by the user on a
port-by-port basis and will be persistent.
Upgrading to version 6.3.1a or later does
not affect the current mode setting, with
the exception of version 6.4.0b or later as
described below.
If upgraded to version 6.4.0b, regardless
of what version was factory installed, all
internal ports will be set to mode 1, and
all external ports to mode 0. The setting
can be changed by the user on a
port-by-port basis and will be persistent.
Implemented support for modes 2 and 3 as
described below. The default setting for all
ports is mode 0, regardless of what Fabric
OS version was previously installed.
However, ports previously set to mode 1 by
the user via the
portcfgfillword
command are persistent, and will therefore
remain at mode 1 after Fabric OS upgrade.
6.3.1a and later
0—Idle for link init, idle for fill word
1—Arb(ff) for link init, arb(ff) for fill word (not supported with EVA or XP storage arrays)
2—Idle for link init, arb(ff) for fill word
3—Initially attempts mode 1 link initialization. If unsuccessful in achieving active state, reverts
to mode 2. Steady state fill word is arb(ff) (not supported with XP storage arrays earlier than
Fabric OS 6.4.0a.)
Modes
Important notes and recommendations
35