HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 75
Effective date, Table 15 Fabric OS 6.4.1b closed defects
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
Table 15 Fabric OS 6.4.1b closed defects (continued) Closed defect summary Solution Discovery issues may occur from the backbone to edge host/target after removal of FCR binding. Fixed in Fabric OS 6.4.1b. nl Workaround prior to upgrade: Reboot the backbone FCRs. After upgrading a Fabric switch to Fabric OS (FOS) v6.4.1.or v6.4.1a, F_Port trunking used to connect any Access Gateways (running FOS v6.1.x or v6.2.x) is not allowed if the Fabric switch does not have a Server Application Optimization (SAO) license installed. This situation eventually results in connectivity loss between the Access Gateway and the Fabric switch when attached with F_Port trunks. Fixed in Fabric OS 6.4.1b. nl Workaround prior to upgrade: Install an SAO license on the switch running FOS v6.2.x (or lower) in AG mode. Frames received on shared area port trunks are improperly Fixed in Fabric OS 6.4.1b. routed causing traffic issues on an HP StorageWorks SAN Director 48- port 8Gb FC Blade in an HP StorageWorks DC SAN Backbone Director. HP StorageWorks Data Center Fabric Manager (DCFM) can be configured to poll for switch configuration and status changes. When DCFM polls the container configuration hosted on an HP StorageWorks Encryption SAN Switch or DC Backbone Switch Encryption Fibre Channel Blade, a resource contention condition can occur. Eventually the contention results in the HP StorageWorks Encryption SAN Switch or DC Backbone Switch Encryption Fibre Channel Blade to fault causing a traffic disruption. Fixed in Fabric OS 6.4.1b. nl Workaround prior to upgrade: Reboot the switch or cycle the blade power (slotpoweroff/on) to recover. When the HP StorageWorks DC SAN Backbone Director is a group leader, the following two issues may occur: the addition of a member node to the encryption group may fail, or the following error is shown for the member node EE state from group leader "EE detection aborted: No EE Detected." Fixed in Fabric OS 6.4.1b. nl Workaround prior to upgrade: Reboot both CPs of group leader HP StorageWorks DC SAN Backbone Director chassis. In a multipath encryption environment, adding SRDF LUNs Fixed in Fabric OS 6.4.1b. to containers results in inconsistencies across the paths. On one path, the LUNs become disabled; on the other path they are enabled. Effective date March 2011 Effective date 75