HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 47
In a 2408 FCoE Switch and a 10/24 FCoE Blade, when CNA sends
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
Table 9 Fabric OS 6.4.0 closed defects (continued) Closed defect summary Solution In a 2408 FCoE Switch and a 10/24 FCoE Blade, when CNA sends FIP Fixed in Fabric OS 6.4.0 ver=0, the switch should not validate the MAC descriptor field for backwards compatibility, but it does, leading to the switch rejecting the login. Incorrect error message is shown in Master log after supportsave was Fixed in Fabric OS 6.4.0 triggered through CLI. The message we get from MAPS are not appropriate. OLS from Mainframe POR not recognized by Condor 4Gb ASIC, resulting Fixed in Fabric OS 6.4.0 in RLIR. An HP Storageworks 1606 SAN Extension Switch crashes after connecting Fixed in Fabric OS 6.4.0 10Gb FCIP ports to a test device that performs various perturbations/ error injection on the port. Fabric OS does not route BLS frames to cascaded CUP. IFCCs seen for timeouts when FICON channels attempt to connect to cascaded MEOSc CUP. Fixed in Fabric OS 6.4.0 In a FICON environment, block port is not displayed in IPL file after host Fixed in Fabric OS 6.4.0 blocks port in-band, due to IPL file not being updated. The switchstatusshow command in CLI on DC SAN Backbone director Fixed in Fabric OS 6.4.0 does not show correct status when core blade is powered off. It reports Core Blades monitor HEALTHY. Strict fabric-wide policy conflict occurs on dual CP switches (directors) after Fixed in Fabric OS 6.4.0 HA failover, leading to switch segmentation. Observed superd_67 error while loading shared libraries: libcurl during Fixed in Fabric OS 6.4.0 disruptive firmware download. Executing configdownload command on HP StorageWorks DC SAN director 10/24 FCoE blade when configured in Virtual Fabric environment, can cause an hafailover and reboot to occur due to FCoE login group management configuration getting uploaded to logical switches other than the default switch. Fixed in Fabric OS 6.4.0 In a FICON environment, RLIR of DRLIR in an interopmode 2 fabric does not Fixed in Fabric OS 6.4.0 contain a domain offset of 0x60 in PID and TAG fields. Ports persistently disabled after cold recovery failover. Fixed in Fabric OS 6.4.0 In a very rare occurrence, HP StorageWorks 1606 Extension SAN switch panic occurred and FCIP I/O stopped during 4 Gb tunnel stress testing. Fixed in Fabric OS 6.4.0 Internal FICON error when doing port swap. Fixed in Fabric OS 6.4.0 Unable to install regular license with downgraded capacity if Universal Trial Fixed in Fabric OS 6.4.0 Slot-Based Licenses were previously installed. Evmd (Event Monitor Daemon) crashed, causing switch to assert/reboot several hours after lscfg --delete when running SMI proxy client or SMI-like interface, due to timer events being processed in the context of a deleted logical switch. Fixed in Fabric OS 6.4.0 Invalid LRC checks/ IFCC seen in Extended XRC FICON Emulation Environment. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Disable FICON XRC Emulation. Port Names in FICUD active CP cache not replicated to backup after Web Fixed in Fabric OS 6.4.0 Tools file activate without edit. Active switch configuration is lost after CTP Workaround prior to upgrade: failover. Port enable / disable states are retained, but portnames and blocked Access the edit window for the file and / unblocked state are not reflected in the Active Configuration view for CUP Port Connectivity. make a change, before activating a CUP configuration file. Fabric OS 6.4.0 fixes 47