HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 70

Fabric OS 6.4.1a fixes, Table 14

Page 70 highlights

Table 13 Fabric OS 6.4.1 closed defects (continued) Closed defect summary Solution Customers may see RAS-1004 Software 'Verify' errors every 3 minutes on Fixed in Fabric OS 6.4.1. each VF, filling up the RASLOG and causing an eventual FFDC event on a switch being managed by DCFM or Web Tools, with VF-enabled and Radius server configured. When running tape operations using tape pipelining in an HP 1606 SAN Fixed in Fabric OS 6.4.1. Extension Switch or HP DC SAN Director Multiprotocol Extension Blade, the FCP_CONF command may be dropped, causing the tape operation to fail. RAM errors are not detected by systemverification diagnostic in the Fixed in Fabric OS 6.4.1. HP 2408 FCoE Switch and HP DC SAN Director 10/24 FCoE Blade. Frame drops and undefined behavior occur while running spinfab. Fixed in Fabric OS 6.4.1. After port enable/disable of a primary port, NPIV PIDs disappear from the cam table entries, which causes data disruption in an HP StorageWorks 4/256 SAN Director and HP StorageWorks 4/256 SAN Director 4/48 blade. Fixed in Fabric OS 6.4.1. The switch is delayed in bringing an F_Port online with certain specific servers Fixed in Fabric OS 6.4.1. that do not cut off light during reboot. The HP 1606 SAN Extension Switch and HP DC SAN Director Multiprotocol Fixed in Fabric OS 6.4.1. Extension Blade require reboots to recover from long TPERF runs that result in inaccurate stats and FCIP tunnel bounces. Several security vulnerabilities are reported by a network vulnerability scan Fixed in Fabric OS 6.4.1. against a fabric with the HP StorageWorks Encryption SAN Switch and the HP StorageWorks DC Switch Encryption FC Blade. During either a firmware download (Fabric OS 6.2.0e to 6.3.0d), or hafailover, the active CP fails to come online completely, requiring a reboot of both CPs to regain hasync. Fixed in Fabric OS 6.4.1. A panic occurs followed by a CP panic, with an Oops: kernel access Fixed in Fabric OS 6.4.1. of bad area message seen in the RASLOG on an HP StorageWorks 400 Multiprotocol Router or HP StorageWorks B-series Multiprotocol Router Blade. Web Tools erroneously able to be launched from Fabric Tree when using auto configured IPv6 address. Fixed in Fabric OS 6.4.1. Tape performance is degraded after a tape drive has been idle for a few Fixed in Fabric OS 6.4.1. hours and then traffic is restarted on the HP 1606 SAN Extension Switch. SCSI command frames are dropped through IFL links in an FCR Fabric. Fixed in Fabric OS 6.4.1. An FCIP tunnel periodically goes down and then recovers when a large Fixed in Fabric OS 6.4.1. number of small FCIP frames are run through a network with a WAN Optimizer present and an FCIP Tunnel in byte streaming mode. This problem is seen on an HP StorageWorks 400 Multiprotocol Router or an HP StorageWorks B-series Multiprotocol Router Blade. An iscsicfg --commit all operation on an HP StorageWorks B-series Fixed in Fabric OS 6.4.1. iSCSI Director Blade does not complete and hangs the switch Telnet session. An hafailover is needed to recover from this state. The switchstatusshow command outputs an invalid switch status rather Fixed in Fabric OS 6.4.1. than the expected "marginal" status on Application (AP) Blades This is caused by the blade handler monitor not properly handling the status of the blades. Fabric OS 6.4.1a fixes Table 14 (page 71) lists defects closed in the Fabric OS 6.4.1a firmware release. 70

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

Table 13 Fabric OS 6.4.1 closed defects
(continued)
Solution
Closed defect summary
Fixed in Fabric OS 6.4.1.
Customers may see RAS-1004 Software 'Verify' errors every 3 minutes on
each VF, filling up the RASLOG and causing an eventual FFDC event on a
switch being managed by DCFM or Web Tools, with VF-enabled and Radius
server configured.
Fixed in Fabric OS 6.4.1.
When running tape operations using tape pipelining in an HP 1606 SAN
Extension Switch or HP DC SAN Director Multiprotocol Extension Blade, the
FCP_CONF
command may be dropped, causing the tape operation to fail.
Fixed in Fabric OS 6.4.1.
RAM errors are not detected by
systemverification
diagnostic in the
HP 2408 FCoE Switch and HP DC SAN Director 10/24 FCoE Blade.
Fixed in Fabric OS 6.4.1.
Frame drops and undefined behavior occur while running
spinfab
.
Fixed in Fabric OS 6.4.1.
After port enable/disable of a primary port, NPIV PIDs disappear from the
cam table entries, which causes data disruption in an HP StorageWorks
4/256 SAN Director and HP StorageWorks 4/256 SAN Director 4/48
blade.
Fixed in Fabric OS 6.4.1.
The switch is delayed in bringing an F_Port online with certain specific servers
that do not cut off light during reboot.
Fixed in Fabric OS 6.4.1.
The HP 1606 SAN Extension Switch and HP DC SAN Director Multiprotocol
Extension Blade require reboots to recover from long TPERF runs that result
in inaccurate stats and FCIP tunnel bounces.
Fixed in Fabric OS 6.4.1.
Several security vulnerabilities are reported by a network vulnerability scan
against a fabric with the HP StorageWorks Encryption SAN Switch and the
HP StorageWorks DC Switch Encryption FC Blade.
Fixed in Fabric OS 6.4.1.
During either a firmware download (Fabric OS 6.2.0e to 6.3.0d), or
hafailover
, the active CP fails to come online completely, requiring a
reboot of both CPs to regain
hasync
.
Fixed in Fabric OS 6.4.1.
A panic occurs followed by a CP panic, with an
Oops: kernel access
of bad area
message seen in the RASLOG on an HP StorageWorks 400
Multiprotocol Router or HP StorageWorks B-series Multiprotocol Router Blade.
Fixed in Fabric OS 6.4.1.
Web Tools erroneously able to be launched from Fabric Tree when using
auto configured IPv6 address.
Fixed in Fabric OS 6.4.1.
Tape performance is degraded after a tape drive has been idle for a few
hours and then traffic is restarted on the HP 1606 SAN Extension Switch.
Fixed in Fabric OS 6.4.1.
SCSI command frames are dropped through IFL links in an FCR Fabric.
Fixed in Fabric OS 6.4.1.
An FCIP tunnel periodically goes down and then recovers when a large
number of small FCIP frames are run through a network with a WAN
Optimizer present and an FCIP Tunnel in byte streaming mode. This problem
is seen on an HP StorageWorks 400 Multiprotocol Router or an HP
StorageWorks B-series Multiprotocol Router Blade.
Fixed in Fabric OS 6.4.1.
An
iscsicfg --commit all
operation on an HP StorageWorks B-series
iSCSI Director Blade does not complete and hangs the switch Telnet session.
An
hafailover
is needed to recover from this state.
Fixed in Fabric OS 6.4.1.
The
switchstatusshow
command outputs an invalid switch status rather
than the expected “marginal” status on Application (AP) Blades This is caused
by the blade handler monitor not properly handling the status of the blades.
Fabric OS 6.4.1a fixes
Table 14 (page 71)
lists defects closed in the Fabric OS 6.4.1a firmware release.
70