HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 68
The standby CP in an HP StorageWorks 4/256 SAN Director
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
Table 13 Fabric OS 6.4.1 closed defects (continued) Closed defect summary Solution The switch or the CP in the director remains in a perpetual reboot state after Fixed in Fabric OS 6.4.1. upgrading from Fabric OS 6.1.x to 6.2.x due to inconsistency between the Workaround prior to upgrade: SSL certificate and the http.enabled setting. The affected switches are: Manually ensure that http.enabled • HP StorageWorks 4/8 or 4/16 SAN Switches matches the SSL certificate by • Brocade 4Gb SAN Switch for HP p-Class BladeSystem configshow http.enabled as admin user. If it is inconsistent with SSL • Brocade 4Gb SAN Switch for HP c-Class BladeSystem certificate requirement, execute • HP StorageWorks 4/32 or 4/64 SAN Switches • HP StorageWorks 4/32B SAN Switch • HP StorageWorks 400 Multiprotocol Router • The standby CP in an HP StorageWorks 4/256 SAN Director /fabos/libexec/webdconfigure as root to set HTTP Enable to yes. Or schedule a window, disable switch and configdownload a file with http.enabled:1 [end] for switches running Fabric OS 6.1.x or versions earlier than 6.1.x to correct the configuration. If the switch is already stuck in a reboot loop, login as root via the serial console, copy and paste the following command string into the console as one line before the next reboot: sed 's/http.enabled:0/http.enabled:1/g' < /etc/fabos/fabos.0.conf > tmp;cp tmp /etc/fabos/fabos.0.conf;cp tmp /mnt/etc/fabos/fabos.0.conf;rm tmp Converged Network Adapters (CNAs) cannot login during a shut/no shut Fixed in Fabric OS 6.4.1. operation on an HP 2408 FCoE switch. Rekey for a LUN gets stuck during long running stress testing that involves Fixed in Fabric OS 6.4.1. repeated ISL and I/O synch link disabling. In Access Gateway mode with Auto Policy enabled, devices are unable to Fixed in Fabric OS 6.4.1. log in because the storage port gets stuck as an N_Port with status Disabled (Fabric Login Failed), and there is no CLI to unlock the port configuration. When Auto Port Configuration is enabled on an Access Gateway, the switch Fixed in Fabric OS 6.4.1. locks down the port as an N_Port if no FLOGI is received within the timeout period. RPCD panic and subsequent switch cold recovery occurs due to internal memory synchronization and corruption issues when changing security settings through Web Tools while there is an active RPC connection from SMI-A. Fixed in Fabric OS 6.4.1. Workaround prior to upgrade: You can avoid this problem by not using your SMI based application until the code upgrade completes. Switch panics occur when simultaneously managed by both DCFM and SMI-A management applications. Fixed in Fabric OS 6.4.1. Web Linker causes active CP to reboot (initiate a cold recovery) when the Fixed in Fabric OS 6.4.1. standby CP is not responsive (stuck in a reboot loop). Due to a timing issue, hosts are unable to access targets for any operational Fixed in Fabric OS 6.4.1. purposes when the number of FCIP circuit configurations on one side of the FCIP Tunnel does not match the other side. After a firmware download, host and target are unable to establish connectivity across a VEX link on an HP 1606 SAN Extension Switch and an HP DC SAN Director Multiprotocol Extension Blade. Fixed in Fabric OS 6.4.1. 68