HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 61
Fabric OS 6.4.0a fixes, Table 9 Fabric OS 6.4.0 closed defects
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
Table 9 Fabric OS 6.4.0 closed defects (continued) Closed defect summary Solution fcipLinkRemfcipEntityWWN of fcipLinkTable do not return the Remote WWN configured. You will not get the remote WWN configured for the fcip tunnel when queried through SNMP. Fixed in Fabric OS 6.4.0 Under certain conditions, after fcoe --disable followed by fcoe --enable , the CNA port WWN appears on fcoe --loginshow but may not appear in nsshow. Fixed in Fabric OS 6.4.0 On stress to fail test, the lisl ports on a logical switch may get stuck in G_Port Fixed in Fabric OS 6.4.0 state after the test of repeated switchdisable/enable commands on the Workaround prior to upgrade: logical switch, followed by hafailover. Use switchdisable/enable on the affected logical switch.. Clean up printf to eliminate error and error message: ssnGet: Unable to get WWN info.sw=0 rc=-5. Adding UNIX "sleep" command to admin commands. Fixed in Fabric OS 6.4.0 Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use other roles to accomplish. The supportsave command shows duplicate cmds output for same LS switches. Fixed in Fabric OS 6.4.0 Port admin screen in Web Tools gets switch not reachable error with Fixed in Fabric OS 6.4.0 return of [WARNING - NOT VIRUS SCANNED] for 1 logical switch. Switch does not broadcast Unsolicited FIP Discovery Advertisements. If the CNA expects UAs from the FCF even if the solicited advertisement had the D bit set, it will logout of the FCF after about 20 seconds. Fixed in Fabric OS 6.4.0 Zone-1004 messages seen with port changing from Hard to Session based zoning. When trapped frames get forwarded to the NameServer for zone check, the switch generates a zone-1004 for all trapped frames, whether the port is already in session or hard-based zoning, due to the port being momentarily switched to hard-based zoning when processing the ELS frame that is forwarded to the NS for zone check. Fixed in Fabric OS 6.4.0 Fabric OS 6.4.0a fixes Table 10 (page 61) lists defects closed in the Fabric OS 6.4.0a firmware release. Table 10 Fabric OS 6.4.0a closed defects Closed defect summary Solution As a result of firmwaredownload, systemverifcation test, or blade Fixed in Fabric OS 6.4.0a insertion, occasionally 10/24 FCoE blade may turn faulty 21. Workaround prior to upgrade: Use slotpoweroff/on the FCoE10-24 to clear the faulty state. In FICON environment, FRU events are not generated on the operator's console for removal or insertion. Fixed in Fabric OS 6.4.0a Rare corner case of Lossless DLS being disabled after several downgrade and upgrade scenarios. A DC SAN Backbone director logical switch with port-based routing, IOD (In-Order Delivery), DLS, and Lossless DLS enabled running Fabric OS 6.3.0b was updated to 6.4.0, and Lossless DLS gets disabled. Fixed in Fabric OS 6.4.0a Workaround prior to upgrade: Re-enable Lossless / IOD on logical switches that were previously enabled. With FMS enabled, after moving all ICL and 254 FC ports into a logical Fixed in Fabric OS 6.4.0a switch with zero based addressing, port 1/0 (area 00) is incorrectly disabled. Fabric OS 6.4.0a fixes 61