HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 61

Fabric OS 6.4.0a fixes, Table 9 Fabric OS 6.4.0 closed defects

Page 61 highlights

Table 9 Fabric OS 6.4.0 closed defects (continued) Closed defect summary Solution fcipLinkRemfcipEntityWWN of fcipLinkTable do not return the Remote WWN configured. You will not get the remote WWN configured for the fcip tunnel when queried through SNMP. Fixed in Fabric OS 6.4.0 Under certain conditions, after fcoe --disable followed by fcoe --enable , the CNA port WWN appears on fcoe --loginshow but may not appear in nsshow. Fixed in Fabric OS 6.4.0 On stress to fail test, the lisl ports on a logical switch may get stuck in G_Port Fixed in Fabric OS 6.4.0 state after the test of repeated switchdisable/enable commands on the Workaround prior to upgrade: logical switch, followed by hafailover. Use switchdisable/enable on the affected logical switch.. Clean up printf to eliminate error and error message: ssnGet: Unable to get WWN info.sw=0 rc=-5. Adding UNIX "sleep" command to admin commands. Fixed in Fabric OS 6.4.0 Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use other roles to accomplish. The supportsave command shows duplicate cmds output for same LS switches. Fixed in Fabric OS 6.4.0 Port admin screen in Web Tools gets switch not reachable error with Fixed in Fabric OS 6.4.0 return of [WARNING - NOT VIRUS SCANNED] for 1 logical switch. Switch does not broadcast Unsolicited FIP Discovery Advertisements. If the CNA expects UAs from the FCF even if the solicited advertisement had the D bit set, it will logout of the FCF after about 20 seconds. Fixed in Fabric OS 6.4.0 Zone-1004 messages seen with port changing from Hard to Session based zoning. When trapped frames get forwarded to the NameServer for zone check, the switch generates a zone-1004 for all trapped frames, whether the port is already in session or hard-based zoning, due to the port being momentarily switched to hard-based zoning when processing the ELS frame that is forwarded to the NS for zone check. Fixed in Fabric OS 6.4.0 Fabric OS 6.4.0a fixes Table 10 (page 61) lists defects closed in the Fabric OS 6.4.0a firmware release. Table 10 Fabric OS 6.4.0a closed defects Closed defect summary Solution As a result of firmwaredownload, systemverifcation test, or blade Fixed in Fabric OS 6.4.0a insertion, occasionally 10/24 FCoE blade may turn faulty 21. Workaround prior to upgrade: Use slotpoweroff/on the FCoE10-24 to clear the faulty state. In FICON environment, FRU events are not generated on the operator's console for removal or insertion. Fixed in Fabric OS 6.4.0a Rare corner case of Lossless DLS being disabled after several downgrade and upgrade scenarios. A DC SAN Backbone director logical switch with port-based routing, IOD (In-Order Delivery), DLS, and Lossless DLS enabled running Fabric OS 6.3.0b was updated to 6.4.0, and Lossless DLS gets disabled. Fixed in Fabric OS 6.4.0a Workaround prior to upgrade: Re-enable Lossless / IOD on logical switches that were previously enabled. With FMS enabled, after moving all ICL and 254 FC ports into a logical Fixed in Fabric OS 6.4.0a switch with zero based addressing, port 1/0 (area 00) is incorrectly disabled. Fabric OS 6.4.0a fixes 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

Table 9 Fabric OS 6.4.0 closed defects
(continued)
Solution
Closed defect summary
Fixed in Fabric OS 6.4.0
fcipLinkRemfcipEntityWWN
of
fcipLinkTable
do not return the
Remote WWN configured. You will not get the remote WWN configured
for the fcip tunnel when queried through SNMP.
Fixed in Fabric OS 6.4.0
Under certain conditions, after
fcoe --disable <port>
followed by
fcoe --enable <port>
, the CNA port WWN appears on
fcoe
--loginshow
but may not appear in
nsshow
.
Fixed in Fabric OS 6.4.0
Workaround prior to upgrade:
Use
switchdisable
/
enable
on the
affected logical switch..
On stress to fail test, the lisl ports on a logical switch may get stuck in G_Port
state after the test of repeated
switchdisable
/
enable
commands on the
logical switch, followed by
hafailover
.
Fixed in Fabric OS 6.4.0
Clean up printf to eliminate error and error message:
ssnGet: Unable
to get WWN info.sw=0 rc=-5
.
Fixed in Fabric OS 6.4.0
Workaround prior to upgrade:
Use other roles to accomplish.
Adding UNIX "sleep" command to admin commands.
Fixed in Fabric OS 6.4.0
The
supportsave
command shows duplicate cmds output for same LS
switches.
Fixed in Fabric OS 6.4.0
Port admin screen in Web Tools gets
switch not reachable
error with
return of [WARNING - NOT VIRUS SCANNED] for 1 logical switch.
Fixed in Fabric OS 6.4.0
Switch does not broadcast Unsolicited FIP Discovery Advertisements. If the
CNA expects UAs from the FCF even if the solicited advertisement had the
D bit set, it will logout of the FCF after about 20 seconds.
Fixed in Fabric OS 6.4.0
Zone-1004 messages seen with port changing from Hard to Session based
zoning. When trapped frames get forwarded to the NameServer for zone
check, the switch generates a zone-1004 for all trapped frames, whether
the port is already in session or hard-based zoning, due to the port being
momentarily switched to hard-based zoning when processing the ELS frame
that is forwarded to the NS for zone check.
Fabric OS 6.4.0a fixes
Table 10 (page 61)
lists defects closed in the Fabric OS 6.4.0a firmware release.
Table 10 Fabric OS 6.4.0a closed defects
Solution
Closed defect summary
Fixed in Fabric OS 6.4.0a
Workaround prior to upgrade:
Use
slotpoweroff/on
the FCoE10-24
to clear the faulty state.
As a result of
firmwaredownload
,
systemverifcation
test, or blade
insertion, occasionally 10/24 FCoE blade may turn faulty 21.
Fixed in Fabric OS 6.4.0a
In FICON environment, FRU events are not generated on the operator's
console for removal or insertion.
Fixed in Fabric OS 6.4.0a
Workaround prior to upgrade:
Re-enable Lossless / IOD on logical
switches that were previously enabled.
Rare corner case of Lossless DLS being disabled after several downgrade
and upgrade scenarios. A DC SAN Backbone director logical switch with
port-based routing, IOD (In-Order Delivery), DLS, and Lossless DLS enabled
running Fabric OS 6.3.0b was updated to 6.4.0, and Lossless DLS gets
disabled.
Fixed in Fabric OS 6.4.0a
With FMS enabled, after moving all ICL and 254 FC ports into a logical
switch with zero based addressing, port 1/0 (area 00) is incorrectly disabled.
Fabric OS 6.4.0a fixes
61