HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 57

Solution, Closed defect summary, Workaround prior to upgrade, Active=Save Mode

Page 57 highlights

Table 9 Fabric OS 6.4.0 closed defects (continued) Closed defect summary Solution With HP StorageWorks 4/8 and 4/16 SAN Switches, and 4Gb BladeSystem Fixed in Fabric OS 6.4.0 switches for p-Class and c-Class BladeSystem, speed negotiation fails when the port is locked as G_Port, and port cannot come online. In a multi-circuit FCIP tunnel configuration with 1606 Extension SAN switch, or multiprotocol extension blade, circuit failover on 1 Gb tunnels may not fail over to other available circuits with two rate limited circuits. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Disable ARL configuration (use minrate and maxrate options on the tunnel and circuit create commands where minrate and maxrate are the same values. Observed VE tunnel bounce after a hareboot on edge switch EX/VEX_Port Fixed in Fabric OS 6.4.0 (Integrated Routing) under heavy load. This is due to fspftimeout during hafailover resulting from neighbor switch disabling the port caused by the switch taking too long to recover. The sfpshow command displays incorrect information for static values of Fixed in Fabric OS 6.4.0 XFPs. Running Fabric OS commands on the default switch with virtual fabrics enabled, after performing multiple cfgenable commands with TI zones enabled, causes a No space left on device error, and no further Fabric OS commands can be executed. Fixed in Fabric OS 6.4.0 Enhancement to the firmware to have an easy single command to know the Fixed in Fabric OS 6.4.0 state of the encryption status. Unable to activate a new PDCM Matrix with Web Tools. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Activate the same PDCM Matrix from Web Tools, with Active=Save Mode checked from Edit CUP Port Connectivity Configuration window. I2C read values of 0xFF and I2C NACK error case not properly handled, Fixed in Fabric OS 6.4.0 causing Fabric Watch to report improbable/unpredictable SFP values. Multicast data traffic is not forwarded out of snooping multiprotocol router Fixed in Fabric OS 6.4.0 port. The ipAdEntIfIndex values@ 1.3.6.1.2.1.4.20.1.2 must correspond to ifIndex Fixed in Fabric OS 6.4.0 values at 1.3.6.1.2.1.2.2.1.1. Fabric Watch reports that the switch is in Marginal status due to marginal Fixed in Fabric OS 6.4.0 ports when no ports report errors. When running a third-party host scan, the http daemon (weblinker.fcg) terminates and restarts several times, causing a temporary management service interruption. Fixed in Fabric OS 6.4.0 Bad zone config message is displayed in the status message window of Fixed in Fabric OS 6.4.0 the zone admin module when user creates and enables a zone configuration from non-primary FCS switch. Proper error message should be given in this case. Virtual target edit operation (changing the LUN and enabling CHAP) causes Fixed in Fabric OS 6.4.0 the virtual target to disappear from the show. You may see virtual target going offline after an edit operation from Web Tools with iSCSI. When Replicate configuration fails due to some of the parameters, DCFM Fixed in Fabric OS 6.4.0 does not list them in the summary message. Web Tools Does Not Copy Effective Zone to Defined Zone DB During configupload, so Defined Zone will not be updated. Fixed in Fabric OS 6.4.0 Fabric OS 6.4.0 fixes 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

Table 9 Fabric OS 6.4.0 closed defects
(continued)
Solution
Closed defect summary
Fixed in Fabric OS 6.4.0
With HP StorageWorks 4/8 and 4/16 SAN Switches, and 4Gb BladeSystem
switches for p-Class and c-Class BladeSystem, speed negotiation fails when
the port is locked as G_Port, and port cannot come online.
Fixed in Fabric OS 6.4.0
Workaround prior to upgrade:
Disable ARL configuration (use
minrate
and
maxrate
options on the tunnel and
circuit create commands where minrate
and maxrate are the same values.
In a multi-circuit FCIP tunnel configuration with 1606 Extension SAN switch,
or multiprotocol extension blade, circuit failover on 1 Gb tunnels may not
fail over to other available circuits with two rate limited circuits.
Fixed in Fabric OS 6.4.0
Observed VE tunnel bounce after a
hareboot
on edge switch EX/VEX_Port
(Integrated Routing) under heavy load. This is due to
fspftimeout
during
hafailover
resulting from neighbor switch disabling the port caused by
the switch taking too long to recover.
Fixed in Fabric OS 6.4.0
The
sfpshow
command displays incorrect information for static values of
XFPs.
Fixed in Fabric OS 6.4.0
Running Fabric OS commands on the default switch with virtual fabrics
enabled, after performing multiple
cfgenable
commands with TI zones
enabled, causes a
No space left on device
error, and no further
Fabric OS commands can be executed.
Fixed in Fabric OS 6.4.0
Enhancement to the firmware to have an easy single command to know the
state of the encryption status.
Fixed in Fabric OS 6.4.0
Workaround prior to upgrade:
Activate the same PDCM Matrix from
Web Tools, with
Active=Save Mode
checked from
Edit CUP Port Connectivity
Configuration
window.
Unable to activate a new PDCM Matrix with Web Tools.
Fixed in Fabric OS 6.4.0
I2C read values of 0xFF and I2C NACK error case not properly handled,
causing Fabric Watch to report improbable/unpredictable SFP values.
Fixed in Fabric OS 6.4.0
Multicast data traffic is not forwarded out of snooping multiprotocol router
port.
Fixed in Fabric OS 6.4.0
The ipAdEntIfIndex values@ 1.3.6.1.2.1.4.20.1.2 must correspond to ifIndex
values at 1.3.6.1.2.1.2.2.1.1.
Fixed in Fabric OS 6.4.0
Fabric Watch reports that the switch is in Marginal status due to marginal
ports when no ports report errors.
Fixed in Fabric OS 6.4.0
When running a third-party host scan, the http daemon (weblinker.fcg)
terminates and restarts several times, causing a temporary management
service interruption.
Fixed in Fabric OS 6.4.0
Bad zone config
message is displayed in the status message window of
the zone admin module when user creates and enables a zone configuration
from non-primary FCS switch. Proper error message should be given in this
case.
Fixed in Fabric OS 6.4.0
Virtual target edit operation (changing the LUN and enabling CHAP) causes
the virtual target to disappear from the show. You may see virtual target
going offline after an edit operation from Web Tools with iSCSI.
Fixed in Fabric OS 6.4.0
When Replicate configuration fails due to some of the parameters, DCFM
does not list them in the summary message.
Fixed in Fabric OS 6.4.0
Web Tools Does Not Copy Effective Zone to Defined Zone DB During
configupload
, so Defined Zone will not be updated.
Fabric OS 6.4.0 fixes
57