HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 71

Table 14 Fabric OS 6.4.1a closed defects, On the HP 2408 24-10GbE w/8-8Gb FC Base FCoE and the HP 2408

Page 71 highlights

Table 14 Fabric OS 6.4.1a closed defects Closed defect summary Solution Under heavy stress, I/O jobs may lead to a faulty encryption blade or switch Fixed in Fabric OS 6.4.1a. for certain third party tapes. Read throughput does not improve after enabling tape read pipelining on Fixed in Fabric OS 6.4.1a. the HP 1606 SAN Extension Switch due to SILI and variable length settings After an i2c reset, FC switch ports report Mod_Val state rather than "Online" Fixed in Fabric OS 6.4.1a. when a Switchshow command is executed and ISL fails to form. This affects all switches except for the following: • HP 8/8 Base (0) e-port SAN Switch • HP 8/8 (8)-ports Enabled SAN Switch • HP 8/24 Base 16-ports Enabled SAN Switch • HP 8/40 Base 24-ports Enabled SAN Switch • HP 8/40 Power Pack+ 24-ports SAN Switch • HP StorageWorks EVA4400 embedded switch module, 8Gb Brocade • Brocade 4Gb SAN Switch for HP p-Class BladeSystem • Brocade 4Gb SAN Switch for HP c-Class BladeSystem • Brocade 8Gb SAN Switch for HP BladeSystem c-Class After a power on reset of a mainframe server, some CHPIDs are in an Invalid Fixed in Fabric OS 6.4.1a. Attachment state in a FICON setup. This is caused by the Management Server (MS) main thread blocking on SNMP notification calls which prevents pending Extended Link Service commands in the message queue from completing within the timeout interval. When there are multiple FCRs connected to the same edge fabric, the server Fixed in Fabric OS 6.4.1a. aborts any tape operation causing the tape backup to fail. When this occurs, the tape backup must be restarted. After port disable/enable or cable pull disruptive testing, when a fabricshow Fixed in Fabric OS 6.4.1a. command is executed, some switches are not visible, some VEx ports remain disabled (Switch not ready for EX_Ports). This occurs when performing portenable of E-ports in an FCR setup with FCIP VEX links. SNMP terminates and does not restart when there is a mismatch between a Fixed in Fabric OS 6.4.1a. configured trap IP address and the configured access control list. FCIP tunnel bounces and occasional frame drops occur during HA Failover Fixed in Fabric OS 6.4.1a.. with heavy traffic load. This is caused by setting GE mode during hafailover. On the HP 2408 24-10GbE w/8-8Gb FC Base FCoE and the HP 2408 24-10GbE w/8-8Gb PwrPk+ FCoE Switches CRC errors on internal links might occur when jumbo frames are transmitted under certain traffic loads below the full line rate. If extensive CRC errors occur, traffic might stop and require disabling and enabling to restore affected user ports. Fixed in Fabric OS 6.4.1a. The standby CP may reboot and the active CP may fail causing an HA Failover due to TSD memory allocation increasing over time. Fixed in Fabric OS 6.4.1a. The host receives a "port type not detected" error when Access Gateway mode is enabled and configured as "auto". Fixed in Fabric OS 6.4.1a. The lfmd daemon terminates and kernel panic occurs while performing a supportsave command.This occurs when there is large number of LISL configurations with virtual fabrics. Fixed in Fabric OS 6.4.1a.. The host is unable to see the target in an E2E topology through a VEX port Fixed in Fabric OS 6.4.1a. of an FCIP link because of improper routing. Fabric OS 6.4.1a fixes 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

Table 14 Fabric OS 6.4.1a closed defects
Solution
Closed defect summary
Fixed in Fabric OS 6.4.1a.
Under heavy stress, I/O jobs may lead to a faulty encryption blade or switch
for certain third party tapes.
Fixed in Fabric OS 6.4.1a.
Read throughput does not improve after enabling tape read pipelining on
the HP 1606 SAN Extension Switch due to SILI and variable length settings
Fixed in Fabric OS 6.4.1a.
After an i2c reset, FC switch ports report Mod_Val state rather than “Online”
when a Switchshow command is executed and ISL fails to form. This affects
all switches except for the following:
HP 8/8 Base (0) e-port SAN Switch
HP 8/8 (8)-ports Enabled SAN Switch
HP 8/24 Base 16-ports Enabled SAN Switch
HP 8/40 Base 24-ports Enabled SAN Switch
HP 8/40 Power Pack+ 24-ports SAN Switch
HP StorageWorks EVA4400 embedded switch module, 8Gb Brocade
Brocade 4Gb SAN Switch for HP p-Class BladeSystem
Brocade 4Gb SAN Switch for HP c-Class BladeSystem
Brocade 8Gb SAN Switch for HP BladeSystem c-Class
Fixed in Fabric OS 6.4.1a.
After a power on reset of a mainframe server, some CHPIDs are in an Invalid
Attachment state in a FICON setup. This is caused by the Management Server
(MS) main thread blocking on SNMP notification calls which prevents pending
Extended Link Service commands in the message queue from completing
within the timeout interval.
Fixed in Fabric OS 6.4.1a.
When there are multiple FCRs connected to the same edge fabric, the server
aborts any tape operation causing the tape backup to fail. When this occurs,
the tape backup must be restarted.
Fixed in Fabric OS 6.4.1a.
After port disable/enable or cable pull disruptive testing, when a fabricshow
command is executed, some switches are not visible, some VEx ports remain
disabled (Switch not ready for EX_Ports). This occurs when performing
portenable of E-ports in an FCR setup with FCIP VEX links.
Fixed in Fabric OS 6.4.1a.
SNMP terminates and does not restart when there is a mismatch between a
configured trap IP address and the configured access control list.
Fixed in Fabric OS 6.4.1a..
FCIP tunnel bounces and occasional frame drops occur during HA Failover
with heavy traffic load. This is caused by setting GE mode during hafailover.
Fixed in Fabric OS 6.4.1a.
On the HP 2408 24-10GbE w/8-8Gb FC Base FCoE and the HP 2408
24-10GbE w/8-8Gb PwrPk+ FCoE Switches CRC errors on internal links
might occur when jumbo frames are transmitted under certain traffic loads
below the full line rate. If extensive CRC errors occur, traffic might stop and
require disabling and enabling to restore affected user ports.
Fixed in Fabric OS 6.4.1a.
The standby CP may reboot and the active CP may fail causing an HA
Failover due to TSD memory allocation increasing over time.
Fixed in Fabric OS 6.4.1a.
The host receives a "port type not detected" error when Access Gateway
mode is enabled and configured as “auto”.
Fixed in Fabric OS 6.4.1a..
The lfmd daemon terminates and kernel panic occurs while performing a
supportsave command.This occurs when there is large number of LISL
configurations with virtual fabrics.
Fixed in Fabric OS 6.4.1a.
The host is unable to see the target in an E2E topology through a VEX port
of an FCIP link because of improper routing.
Fabric OS 6.4.1a fixes
71