HP 316095-B21 FW 08.01.00 McDATA EFCM Basic User Manual (620-000240-000, Novem - Page 233
Error 217: All Attached Nodes are in the Zone, Error 216: No Attached Nodes Exist
UPC - 808736488280
View all HP 316095-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 233 highlights
Message Description Action Error 215: Zone Set Size Exceeded The local work area zone set has outgrown the size limitations imposed by the Command Line Interface. Reduce the size of the zone set to meet requirements. This can be a reduction in the number of zones in the zone set, a reduction of members in a zone, or a reduction of zone name lengths. Message Description Action Error 216: No Attached Nodes Exist There are no attached nodes. To add more members, attach more devices to the switch or add the members by WWN or Domain ID and port. Message Description Action Error 217: All Attached Nodes are in the Zone All the attached nodes are already in use. To add more members, attach more devices to the switch or add the members by WWN or Domain ID and port. Message Description Action Error 218: Invalid Port Number The value entered for the port number is invalid Enter a port number within the range supported by your director or switch. Message Description Action Error 219: Invalid Port Type The port type configured is invalid. A port may be configured to be an eport, gport, or fport. Be sure the port is configured appropriately and re-submit the command. On the 12-port and 24-port switches only, fxport and gxport types are also supported. On the 12-port switch, the Fabric Capable feature must be installed to configure a E_Port, G_Port, or Gx_Port. A-39