HP 3380 Service Manual - Page 165
Right plate assembly, CAUTION,
View all HP 3380 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 165 highlights
CAUTION Right plate assembly 1. Separate the scanner from the printer (see Separation of the scanner from the printer), and remove the left-side door and back cover (see Left-side door and Back cover). 2. Remove the front cover, print-cartridge door, and front guide assembly (see Front-cover assembly, Print-cartridge door, and Front guide assembly). 3. Remove the solenoid (see Solenoid). 4. Remove the fan assembly (see Fan assembly). 5. Use a small, flat-blade screwdriver to release the locking tab inside of the printer, and slide the solenoid clutch gears off of the shaft and away from the left side of the product. The solenoid-clutch-gear assembly is made up of two gears with a small compression spring between them. Do not separate these gears when removing them or you might lose the spring. Figure 5-84. Note Remove the right plate assembly (1 of 2) 6. Remove seven screws (callout 1). If you have not already removed the fuser, remove the fuser screw and the largest gear on the fuser (these are already removed in the photo), and remove the 69T gear (callout 2). ENWW Printer assemblies 149