HP 35s HP 35s scientific calculator - User Guide - Page 223
Programming Techniques, Program Lines, In RPN mode, Description, Using Flags.
UPC - 000000000000
View all HP 35s manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 223 highlights
It is good practice in a program to make sure that any conditions you will be testing start out in a known state. Current flag settings depend on how they have been left by earlier programs that have been run. You should not assume that any given flag is clear, for instance, and that it will be set only if something in the program sets it. You should make sure of this by clearing the flag before the condition arises that might set it. See the example below. Example: Using Flags. Program Lines: (In RPN mode) Description: Clears flag 0, the indicator for In X. Clears flag 1, the indicator for In Y. Prompts for and stores X If flag 0 is set... ... takes the natural log of the X-input Stores that value in X after flag test Prompts for and stores Y If flag 1 is set... ... takes the natural log of the Y-input Stores that value in Y after flag test Displays value Displays value Checksum and length: 16B3 42 If you write lines S002 CF0 and S003 CF1(as shown above), the flags 0 and 1 are cleared so lines S006 and S010 do not take the natural logarithms of the X- and Yinputs. If you replace lines S002 and S003 by SF 0 and CF 1, then flag 0 is set so line S006 takes the natural log of the X-input. If you replace lines S002 and S003 by CF 0 and SF1, then flag 1 is set so line S010 takes the natural log of the Y-input. Programming Techniques 14-13