HP 35s HP 35s scientific calculator - User Guide - Page 251
Checksum and length: 9C0F 15
UPC - 000000000000
View all HP 35s manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 251 highlights
Program Lines: (In RPN mode) Description Displays, prompts for, and, if changed, stores x-value in X. If flag 0 is set . . . Branches to K001 Branches to M001 Stores yˆ -value in Y. Displays, prompts for, and, if changed, stores y-value in Y. If flag 0 is set . . . Branches to O001 Branches to N001 Stores xˆ in X for next loop. Loops for another estimate. Checksum and length: C3B7 36 This subroutine calculates yˆ for the straight-line model. Calculates yˆ = MX + B. Returns to the calling routine. Checksum and length: 9688 15 This subroutine calculates xˆ for the straight-line model. Calculates xˆ =(Y - B) ÷ M. Returns to the calling routine. Checksum and length: 9C0F 15 This subroutine calculates yˆ for the logarithmic model. Calculates yˆ = M In X + B. Returns to the calling routine. Statistics Programs 16-5